Maintenance Of Your Water Heater; Replacement Parts; Removing The Manifold/Burner Assembly; Removing The Burner From The Manifold/Burner Assembly - Kenmore 153.336930 Use & Care Manual

30/40 gallon tall
Hide thumbs Also See for 153.336930:
Table of Contents

Advertisement

Replacement
Parts
IMPORTANT: The following maintenance procedures are for the
FVIR System components and should be performed by a qualified
technician.
Replacement parts may be ordered from Sears Parts and Service
Centers or by calling 1-800-4-MY-HOME (1-800-469-4663). When
ordering replacement parts, always have the following information
ready:
1.
model, serial, and product number
2.
type of gas
3.
item number
4.
parts description
See the Parts Order List section for a list of available repair parts.
Removing
the Manifold/Burner
Assembly
1.
Turn the gas
control/temperature
knob to the
"OFF"
position (Figure 28).
2.
Before performing any maintenance, it is important to turn off
the gas supply to the water heater at the manual gas shut-off
valve. This valve is typically located beside the water heater.
Note the position of the shut-off valve in the open/on position,
then proceed to turn it off (Figure 2).
With the unit shut-off, allow sufficient time for the water heater
to cool before performing any maintenance.
3,
GAS
CONTROL/
TEMPERATURE
KNOB
4,
5.
6,
IGNITER
WHITE
_i_ _
WIRE
IGNITER_"_i
_ _
',_ (RIGHT
LEAD
n
_
_
,"'
SIDE)
IJ PILOT
_,
RED
W RE
IGNITER_,i
TUBE
WIRE
',",
(LEFT
SIDE)
MANIFOLD TUBE
FIGURE 28.
Remove the outer door.
Disconnectthe followingfrom the gas controlvalve/thermostat:
pilot tube (7/16" wrench), igniter wire (from the igniter lead
wire), and manifoldtube (3/4"wrench). See Figure28.
Disconnect the white and red wires from the gas control
valve/thermostat (Figure 28). Use needle nose pliers to
grip the connector(s).
IMPORTANT: Grip the connector
carefully to prevent damage.
Do not grip or pull the
wires themselves.
7.
Grasp the manifold tube and push down slightly to free the
manifold tube and pilot tube.
8.
Remove
the screws
(1/4"
nut
driver)
securing
the
manifold/burner
assembly
to the combustion
chamber.
See Figure 29.
9.
Carefully remove the manifold/burner assembly from the
combustion chamber. BE SURE NOT TO DAMAGE ANY
INTERNAL PARTS.
GAS CONTROL
VALVE/THERMOSTAT
THERMOPILE
AND
\
SWITCH
WIRE
GAS CONTROL/
_
_
CONNECTIONS
TEMPERATU
RE KNOB
_
,_!
PIEZO IGNITER
BUTTO
PILOT TUBE ___1i
'
,i:I:!,:\_)
_MANIFOLD
TUBE
VIEWPORT
_
_.,r_
i
i_JI
_Pff_,_
THERMAL
SW TCH
/-
/.
MANIFOLD
SCREW
(2)
MANIFOLD
COMPONENT
BLOCK
FIGURE 29.
Removing
the Burner from the Manifold/
Burner Assembly
Natural Gas (Low Nox) & L.P. Gas Burner
1.
Take off the burner by removing the two (2) screws located
underneath the burner.
2.
Check the burner to see if it is dirty or clogged. The burner
may be cleaned with soap and hot water (Figure 30).
IMPORTANT: DO NOT remove the orifice.
f_j
PILOT
ASSEMBLY
_
(BOTTOM
VIEW)
FIGURE 30.
Replacing
the Pilot/Thermopile
Assembly
1.
Remove
the
manifold
door assembly
as described
in
"Removing the Manifold/Burner Assembly" section.
2.
Remove the burner to access the pilot/thermopite assembly.
Remove and keep the screws securing the bumer to the
manifold (Figure 30).
IMPORTANT: DO NOT remove the
orifice.
3.
Remove the screw securing the pilot/thermopile assembly to
the pilot bracket and keep for reuse later (Figure 31 ).
4.
Lift the retainer
clip straight
up from the back of the
manifold component block (using a flat-blade screwdriver),
then
remove
the manifold
component
block from the
manifold door (Figure 31). IMPORTANT: Be careful not to
bend or alter the position of the pilot tube.
It will be used
as a bending template for the new pilot assembly. Note the
placement!order of the wires in the manifold component block.
5.
Lift the pitot/thermopite assembly (including the igniter wire)
from the manifold assembly.
31

Advertisement

Table of Contents
loading

This manual is also suitable for:

153.336940153.336931

Table of Contents