INSTALLATION--GAS
CONNECTIONS
Ill
PROVIDE ADEQUATE
GAS SUPPLY
This cooktop
is designed
to operate
on
natural
gas at 4" of water
column
manifold
pressure
and 7" of water
column
(W.C.)
supply
pressure.
It is shipped
from
the
factory
set for natural
gas. The convertible
pressure
regulator
supplied
with
the unit
must
be connected
in series
with
the
manifold
of the cooktop
and must
remain
in
series
with the supply
line
regardless
of
whether
natural
or L.P. gas is being
used.
FOR PROPER OPERATION,
THE MAXIMUM
INLET
PRESSURE
TO THE REGULATOR
MUST
BE NO MORE THAN
14" OF WATER
COLUMN
PRESSURE.
For checking
the
regulator,
the inlet
pressure
must
be at least
1" W.C.. (or 3.4 KPA) greater
than the
regulator
output
setting.
If the regulator
is set
for 4" W.C. of water
column
pressure,
the
inlet
pressure
must
be at least 5" W.C. If the
regulator
is set for
10" W.C., the inlet
pressure
must
be at least
11" W.C.. The gas supply
line
to the cooktop
should
be 1/2" or 3/4" pipe.
_-I INSTALL REGULATOR
NEVER
REUSE OLD CONNECTORS
WHEN
INSTALLING
THIS COOKTOP.
-&WARNING:
Never reuse old
flexible
connectors.
The use of old flexible
connectors
can cause gas leaks and personal
injury. Always
use new flexible
connectors
when
installing
a gas appliance.
Screw
a section
of pipe
onto the inlet end of the
pressure
regulator
and
install the coupling.
Pressure
_-]
Regulator
_J
Coupling
_
To reduce
the likelihood
of gas leaks,
apply
teflon
tape or a thread
compound
approved
for use with
LP or Natural
gases to all
threaded
connections.
[]
INSTALL REGULATOR
ONTO
BURNER BOX BOTTOM
Screw
the
regulator
onto
the burner
box
bottom
pipe
connection.
Make
sure the
top
of the
regulator
is
facing
towards
the
cabinet
front,
easily
accessible
through
the
cabinet
doors.
Pressure
_
Regulator
Coupling_
Shut-Off
q,
Valve
_*_
I
I
J
I
_TJ
LI
i\
II Electrical
I Outlet 12"
I
Below
Countertop
_-I COMPLETE
CONNECTION
WITH A COUPLING
Complete
the
connection
between
the
regulator
pipe
coupling
and
the shut-off
valve.
I
I
"I
Pressure
Regulator
Coupling_[_
Shut-Off
f/,
Valve
_
JqJ
LI
II Electrical
I Outlet 12"
I
Below
Countertop