Wiring Diagram (Engine Start/Shutdown Relay) - MULTIQUIP MAYCO LS600 Operation And Parts Manual

Mayco series concrete pump deutz bf4l914 diesel engine
Table of Contents

Advertisement

LS600 PUMP — WIRING DIAGRAM (ENGINE START/SHUTDOWN RELAY)
CONTROL BOX INTERIOR
ENGINE START/SHUTDOWN RELAY
DIGITAL READOUT
MODULE
J1-9
+12 VDC
OUTPUT
86
RELAY
K1
85
FUSE HOLDER
P/N EM98066
FUSE NOT
25A
INCLUDED
W/KIT
PAGE 74 — MAYCO LS600 PUMP — OPERATION AND PARTS MANUAL — REV. #4 (9/15/11)
YELLOW
WHITE
30 AMP
FUSE
F1
D1
RED
BLACK
LOFA
K1-87
RED
BLK
ECU
GND.
BLACK POTTED
BOX
NOTE:
ALL WIRES ARE 12 AWG.
UNLESS OTHERWISE SPECIFIED
Figure 65. Engine Start/Shutdown Relay
L
T R O
C O N
R
R E A
B O X
V I E W
J1
J2
J3
J4
J5
J1
J1
8 7 6 5
8 7 6 5
4 3 2 1
4 3 2 1
J3
J3
8 7 6 5
8 7 6 5
4 3 2 1
4 3 2 1
INSIDE
OUTSIDE
CONTROL
CONTROL
BOX
J3 MALE
BOX
INTERFACE
P3
CONNECTOR
(WHITE)
1
INSIDE
OUTSIDE
CONTROL
CONTROL
BOX
BOX
K1-87A
J1 MALE
INTERFACE
CONNECTOR
K1-30
(YELLOW)
P1
RED
7
INSIDE
OUTSIDE
8
CONTROL
CONTROL
BOX
BOX
YELLOW
WHITE
YELLOW
WHITE
YELLOW
UNFUSED 35A
SUPPLY
ENGINE SOLENOID
P3
4
FUEL SOLENOID
J1
(SHUT-DOWN)
RED
6
BLK
5
RELAY K1
(REAR VIEW)
86
30
87A
87
85
P/N 52016