Inspection - MULTIQUIP MAYCO LS600 Operation And Parts Manual

Mayco series concrete pump deutz bf4l914 diesel engine
Table of Contents

Advertisement

CAUTION - GENERAL SAFETY GUIDELINES
NEVER operate the pump in a
confined area or enclosed area
structure that does not provide ample
free flow of air .
ALWAYS wear approved eye and
hearing protection before
operating the pump .
NEVER operate the pumps's engine
with the engine hood removed. The
possibility exists of hands , long hair ,
and clothing becoming entangled with
the V-belt, causing injury and bodily
harm.
NEVER place hands or feet inside the hopper .
ALWAYS make while the engine is running. ALWAYS
shut down the engine before performing any kind of
maintenance service on the pump.
See Figures 5, 6, and 7 for the location of
any control or component referenced in this
section.
BEFORE STARTING
1. Read safety instructions at the
beginning of manual.
2. Clean the entire pump , removing dirt and dust, par-
ticularly the engine cooling air inlet, and heat exchanger.
3. Check the air filter for dirt and dust. If air filter is dirty,
replace air filter with a new one as required.
4. Check fastening nuts and bolts for tightness.
WARNING - EXPLOSIVE FUEL
Handle fuel safely. Diesel fuel is highly flammable and
can be dangerous if mishandled. DO NOT smoke while
refueling. DO NOT attempt to refuel pump if the engine
is hot or running. ALWAYS allow engine to cool before
refueling.
MAYCO LS600 PUMP — OPERATION AND PARTS MANUAL — REV. #4 (9/15/11) — PAGE 23
LS600 PUMP — INSPECTION
FUEL CHECK
1.
Check the fuel gauge built into the fuel tank cap
(Figure 8) to determine if the pump's engine fuel is
low. Refuel as needed.
WARNING - EXPLOSIVE FUEL
Diesel fuel is extremely flammable,
and its vapors can cause an explosion
if ignited. DO NOT start the engine
near spilled fuel or combustible fluids.
DO NOT fill the fuel tank while the
engine is running or hot.
DO NOT overfill tank, since spilled fuel could ignite if it
comes into contact with hot engine parts or sparks from
the ignition system. Store fuel in approved containers,
in well-ventilated areas and away from sparks and
flames. NEVER use fuel as a cleaning agent.
Figure 8. Fuel Cap Gauge
2.
If fuel is low, remove fuel filler cap and fill with #2
diesel fuel (Figure 9).
Figure 9. Adding Diesel Fuel