Download Print this page

Specifications; Troubleshooting - Honeywell ADEMCO 6150RF Installation And Setup Manual

Keypad/transceiver
Hide thumbs Also See for ADEMCO 6150RF:

Advertisement

Deleting, Replacing, or Editing Wireless Keys
Use the following procedure to delete, replace, or change any of the programming for a wireless key.
Step
Action
1
Enter the Program mode by pressing the [1] and [3] keys
simultaneously for a few seconds within 30 seconds after applying
power.
Enter [5] (Wireless Key Editing). Enter the device number for the
2
wireless key you want to edit. This must be a device that has its
serial number programmed in the 6150RF already.
To delete the serial number, press [✱], then press [9], then press [✱]
again.
To exit without deleting the serial number, press the [#] key.
Press the [✱] key to continue.
To change any of the programming for the wireless key, perform one
3
of the following step in the Programming for an Installation WITH
Local Wireless Keys section.
For the user code, perform step 5.
For the loop functions, perform steps 6 and 7.
For the on-board relay assignment, perform steps 8 to 9.
When you have completed editing the wireless keys, press the [✱]
4
key twice to exit the Program mode.
Note:
Upon exiting the Program mode, the 6150RF alternately flashes "Ad," the 2-digit keypad address, and
the 2-digit receiver address. If either of these is incorrect, repeat steps 1 through 3 in the
Programming for an Installation Without Local Wireless Keys section.

Troubleshooting

The following error messages cause the 6150RF to produce rapid beeps for 5 seconds. The table below describes
the error messages and the corrective actions.
Display
Probable Cause
Low battery in the wireless
Lb
key
OC
Open circuit
1C
Incompatible connection
Check 09
1.
2.

Specifications

Physical:
6-1/4" H x 4-7/8" W x 1" D
(158.75mm x 123.8mm x 25.4mm)
Wiring:
Refer to Wiring Table on page 2
Range:
200' nominal
Frequency:
345 MHz
6150RF Receiver is not
communicating
Another device on the
keypad terminals is
not communicating to
the control panel
Corrective Action
1.
Replace the battery if the wireless key has a replaceable
battery.
2.
Replace the transmitter if the wireless key does not have a
replaceable battery.
Verify that the Data Out (DO) wire is connected properly.
Verify that the control panel is not a First Alert-type control
panel.
1.
Verify that the Data In (DI) wire is connected properly.
2.
Verify the wiring connections between the control and all
other devices.
Voltage:
Current:
Relay:
Sounder:
Display
Alternately flashes "oo" and
two dashes.
Flashes the device number
and a hyphen.
Once the device number is
entered, alternately flashes
"d" with the device number;
and the serial number.
Alternately flashes "d" with
the device number; and "--."
12VDC
Standby ..........................80mA
Backlighting on and
Sounder on......................105mA
Normally Open, 1A, 28VDC
Piezo-electric (fire alarm is loud pulsing
tone; burglary/audible panic alarm is
continuous tone)
- 7 -

Hide quick links:

Advertisement