Messages List

When any of the messages listed below appears on the projected image, address the problem in
accordance with the table below.
Message
High temp.! Lamp off in
1 min.
Frequency is out of
range!
Please check Input-A
Signal Sel.
Please replace the Lamp
and clean the Filter.
Not applicable!
The panel keys are
locked!
34
Messages List
Meaning/Remedy
Check the items below.
• Check to see if nothing is blocking the ventilation holes.
• Check to see if the air filter is not clogged.
Change the output setting of the connected equipment to one
for signals supported by the projector.
Set "Input-A Signal Sel." to "Auto" or select the input signal
type to suit to the input signal.
Replace the lamp with a new one and clean the air filter. The
message appears whenever you turn on the power until you
replace the lamp and reset the lamp timer.
Invalid key pressed.
"Panel Key Lock" is set to "On."
Page
3, 39
44
24
37, 39
24