Main Menu; Input - Optoma HQView-320 Operating Instructions Manual

Image scaler
Table of Contents

Advertisement

A factory reset can also be applied when pressing the factory reset key combination at power up. The
keys have to be kept pressed for about 10 seconds until the RGB(S) input LEDs stop flashing. If the
keys are released during that 10 seconds period the system will get into Updater mode (see chapter 5)
since the Menu key is part of this key combination.
2 – YPbPr / RGB(S) video input
3 – DVI-I connector featuring a DVI-D input and a VGA input
4 – DVI-I output connector (only the digital DVI-D is supported, HDMI 1.3 receivers can be connected
with a DVI/HDMI adapter cable)
5 – TCP/IP port
6 – USB port
7 – RS232 port
8 – Power supply connector
3.3.

Main Menu

The main menu lists the input channel select item, 6 sub menus, and a menu item for automatic setup
of VGA modes. The 6 sub menus are Output, Color, Geometry, Enhancement, System and Multiple Unit
(only HQView-310 and HQView-320).
On each menu page an Exit menu item is available to leave the menu or submenu.
The menus are contextual, therefore some adjustments are not applicable to all signal types or
operating modes, in which case those non-applicable functions will be ghosted/ greyed out and are not
accessible.
All menus have a top status line and a bottom line indicating the firmware revision number. In the status
line the currently selected input channel is indicated and the detected mode is identified. The firmware
revision number displays the revision number of the boot-loader behind BL, the revision number of the
firmware behind FW and the model 300S, 310, 320 type of the unit.
To set up your HQView-3xx it is recommended that you follow this procedure:
Choose the correct output mode and parameters to suit your screen or projector.
Select the correct input signal.
Set the input levels and features appropriately to optimize the appearance of your image.
Set any other parameters to suit your application.
Note: All Input parameters are specific to your chosen input channel and input signal type, they are not
global to the unit. All Output parameters are global
3.4.

Input

The list of available inputs can be scrolled through using the Up and Down keys. The new input is not
selected until the Menu key is pressed.
The list of inputs are: Component, VGA, DVI and Test Pattern.
Test patterns can be generated by HQView-3xx without needing an input connected. When Test Pattern
is selected as the input, the required test pattern can be chosen with the menu navigation up/down keys
when the menu system has been exited, or it can be selected in menu/System/Input Config/Test Pattern
Setup.
©
Calibre UK Limited Issue 2.40
nd
22
April 2013
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hqview325Hqview-300 seriesHqview-300sHqview-310

Table of Contents