  • Page 1 HQView-500 Series Operating Instructions Version 2.40...
  • Page 2 Calibre UK Ltd ("Calibre"). Failure to comply with this condition may result in prosecution.
  • Page 3: Table Of Contents

    PiP Position 3.9. Multiple Unit 3.9.1. Auto Zoom 3.9.2. Units Wide/Units High 3.9.3. Horizontal Pos/Vertical Pos 3.9.4. Blend Width 3.9.5. Blend Curve Type 3.9.6. Black-Level Uplift 3.9.7. Reduce Black-Level Uplift Width 3.10. Enhancement © Calibre UK Limited Issue 2.40 April 2013...
  • Page 4 Discovery Tool 4.4. Software Operation 4.4.1. File Upload FIRMWARE UPDATE 5.1. Introduction 5.2. Updating Firmware ENVIRONMENTAL AND EMC 6.1. Recommended Operating Conditions 6.2. Storage 6.3. CE and FCC Compliance 6.4. PAT Testing © Calibre UK Limited Issue 2.40 April 2013...
  • Page 5: Safety Warning

    WITHDRAW THE MAINS PLUG FROM THE MAINS OUTLET BEFORE YOU START. THIS EQUIPMENT CONTAINS NO USER SERVICEABLE PARTS. REFER ALL SERVICING AND MAINTENANCE TO QUALIFIED SERVICE PERSONNEL. TO AVOID EXPLOSION, DO NOT OPERATE THIS EQUIPMENT IN AN EXPLOSIVE ATMOSPHERE © Calibre UK Limited Issue 2.30 April 2013...
  • Page 6: Introduction

    HQView-520/530 adds free form warp capability for non-flat screens in single or multi projector installation. Warp maps created with the PC tool “Warp Generator” can be uploaded into HQView- 520/530 and processed accordingly. © Calibre UK Limited Issue 2.30 April 2013...
  • Page 7: Packing List

    .pdf 1.2. Packing List HQView-5xx is supplied with the following: 1) This manual 2) 3 pin plug IEC mains cable 3) DVI-D output cable 4) CD containing manuals and useful applications © Calibre UK Limited Issue 2.30 April 2013...
  • Page 8: Hqview-5Xx System Description

    SD-SDI, HD-SDI and 3G-SDI YCbCr 4:2:2 serial digital component video Input impedance: 75 ohms. SMPTE 292M, SMPTE 259M-C and SMPTE 424M compliant, accepts 484i, 576i, 720, 1080i and 1080p single link formats at 270Mb, 1.485Gb or 2.97Gb rates. © Calibre UK Limited Issue 2.30 April 2013...
  • Page 9: Computer (Svga) Inputs Vesa Formats

    MAC computer as the source. A MAC will encrypt it’s output signal if a compliant device is seen attached to it’s output. By turning off the HQView processor’s compliance the MAC will see a non- compliant device and therefore will not encrypt its output. © Calibre UK Limited Issue 2.30 April 2013...
  • Page 10: Hqview-5Xx Control

    HQVIEW-5XX CONTROL 3.1. Menu Tree HQView-500S Menu Tree Level Level Level Level © Calibre UK Limited Issue 2.30 April 2013...
  • Page 11 © Calibre UK Limited Issue 2.30 April 2013...
  • Page 12 © Calibre UK Limited Issue 2.30 April 2013...
  • Page 13 © Calibre UK Limited Issue 2.30 April 2013...
  • Page 14 © Calibre UK Limited Issue 2.30 April 2013...
  • Page 15 HQView-510, 520 and 530 have a Multiple Unit Menu instead of the HQView-500S PiP Menu and they feature embedded Warp. Please note : HQView-510, 520 and 530 can however be rebooted in HQView-500S mode with PiP instead of Multiple Unit capability. Level Level Level Level © Calibre UK Limited Issue 2.30 April 2013...
  • Page 16 © Calibre UK Limited Issue 2.30 April 2013...
  • Page 17 Level HQView-530 has a front panel LCD which can be used alone to set-up the unit. Consequently, there is a menu item to activate or disable the OSD. Level Level Level Level © Calibre UK Limited Issue 2.30 April 2013...
  • Page 18: Introduction

    6 – Jog wheel: The wheel is used for navigating through the menu system and making value changes. The jog wheel has a push function. Pushing the knob has the same effect as pushing the Menu key. © Calibre UK Limited Issue 2.30 April 2013...
  • Page 19 7 – YPbPr / RGB(S) video input 8 – DVI-D and VGA output 9 – 3G-SDI output 10 – USB port 11 – TCP/IP port 12 – RS232 port 13 – Power supply connector © Calibre UK Limited Issue 2.30 April 2013...
  • Page 20: Main Menu

    This menu contains adjustments associated with setting up outputs from the unit. The items are organized in three sub menus, Display Type, Gamma/Color/Crush and Output Config. Use the up and down keys or jog dial to scroll to the required item and press the Menu key. © Calibre UK Limited Issue 2.30 April 2013...
  • Page 21: Display Type

    Frame Rate setting in the Output Config menu includes 48Hz. Otherwise a 24Hz input mode is displayed at 60Hz. 48Hz input modes will be output at 48Hz if the Frame Rate setting in the Output Config menu includes 48Hz. Otherwise it is displayed at 50Hz. © Calibre UK Limited Issue 2.30 April 2013...
  • Page 22: I/O Lock

    Note: If e.g. an adjustment to reduce the level of red in the image is required, select a higher number for the (input) Colour Temp in the Colour menu, or a lower number for the Native Colour Temp in the Output menu. © Calibre UK Limited Issue 2.30 April 2013...
  • Page 23: Output Config

    Auto refresh rate configuration discussed in paragraph 3.5.3. 3G-SDI Data Map 720p and 1080i HD-SDI data can be output in YCbCr 4:2:2, YCbCr 4:4:4 or RGB 4:4:4 mode. 3GSDI data can be output as Level A or B data. © Calibre UK Limited Issue 2.30 April 2013...
  • Page 24: Colour

    Set this value to match the native gamma of the input signal. Input gamma and output gamma both default to 2.2. If they are both set to the same value, there is no effect on the image. © Calibre UK Limited Issue 2.30 April 2013...
  • Page 25: Geometry

    For convenience all settings can be reset with one button provided in the submenus. 3.7.4. Picture Format Settings: Standard, Full Screen, Crop, Anamorphic © Calibre UK Limited Issue 2.30 April 2013...
  • Page 26: Overscan

    With the Pan and Tilt sliders panning within the image in horizontal and vertical direction is possible. Off raster panning is allowed, i,e, the image can be shifted outside the active area of the display. For convenience the PTZ settings can be reset with one button. © Calibre UK Limited Issue 2.30 April 2013...
  • Page 27: Pip

    Selects the quadrant where to show the PiP image. When Free H/V is selected the horizontal and vertical PiP positioning sliders become available and the PiP can be moved over the screen. © Calibre UK Limited Issue 2.30 April 2013...
  • Page 28: Multiple Unit

    Note:- This function can be used in conjunction with the item below to select the blend regions to be provided even when auto zoom is turned off © Calibre UK Limited Issue 2.30 April 2013...
  • Page 29: Horizontal Pos/Vertical Pos

    Setting the black level uplift for the middle of an edge also sets the black level uplift for the two adjacent corners, and if needed the corners can then be set individually. © Calibre UK Limited Issue 2.30 April 2013...
  • Page 30: Reduce Black-Level Uplift Width

    CCS is a filter to reduce luminance to chrominance cross talk of composite video signals (only) which appears as a coarse rainbow pattern or random colors in regions of fine details. 3.10.4. Flicker Filter By default the filters are off. © Calibre UK Limited Issue 2.30 April 2013...
  • Page 31: System

    The DVI-I connector will accept either DVI-D or VGA analogue inputs. The DVI-I channel can be configured for either. The equalisation of the DVI interface can be boosted to allow for extended cable length. © Calibre UK Limited Issue 2.30 April 2013...
  • Page 32 The DDC can be taken off line. When setting HDCP Input to off HQView pretends to be non HDCP compliant forcing the source to not encrypt data which is not copy protected. © Calibre UK Limited Issue 2.30 April 2013...
  • Page 33: Display Mode

    Display Mode The “Display Mode” can be set to either Low Latency or Best Picture. In Best Picture optimum image processing is applied, whereas in Low Latency mode the lowest latency is achieved. © Calibre UK Limited Issue 2.30 April 2013...
  • Page 34: Menu Settings

    PiP mode. Selecting the PiP mode will effectively boot the HQView-510/520/530 to emulate a HQView-500S. A HQView-500S has PiP/PaP/PoP capability but no edge blend. The Operation Mode can be switched back to Multiple Unit. © Calibre UK Limited Issue 2.30 April 2013...
  • Page 35: Remote Control Web Server

    MAC address. The MAC address of the box can be found in the System/Network Settings menu. Note: This is for use on a network not on a single wire connection. © Calibre UK Limited Issue 2.30 April 2013...
  • Page 36: Software Operation

    // e.g. 1280 pixels horizontally needs 427 values (1024/3 = 426.67, rounded up) // So the size (s) of the image data is calculated like this: // s = CEILING(ImageWidth /3 ) * 4 * ImageHeight © Calibre UK Limited Issue 2.30 April 2013...
  • Page 37 // 000A08 3F FF FF FF 3F FF FF FF (beginning of second line) // ... // 2ED608 3F FF FF FF 3F FF FF FF (beginning of last line) // s = CEILING(1920 /3 ) * 4 * 1200 = 3072000 bytes © Calibre UK Limited Issue 2.30 April 2013...
  • Page 38: Firmware Update

    Update Firmware button has to be pressed and the firmware download to the HQView-5xx into non volatile flash RAM starts. After completion of the download HQView-5xx needs to be restarted normally (without pressing the Menu key) for the change to take effect. © Calibre UK Limited Issue 2.30 April 2013...
  • Page 39: Environmental And Emc

    You have to be careful where you connect the earth bond test lead when using 8A or 10A. It is to the metal chassis that you must connect the test lead (mains earth). DO NOT CONNECT to the connectors of the rear panel (signal earth). The HQView/LEDView may never work again. © Calibre UK Limited Issue 2.30 April 2013...