Input Gamma; Geometry; Horizontal/Vertical Position; Edge Control - Optoma HQView-320 Operating Instructions Manual

Image scaler
Table of Contents

Advertisement

3.6.9.

Input Gamma

Settings: Gamma 1.0, Gamma 1.5, Gamma 2.2, Gamma 2.8
Set this value to match the native gamma of the input signal. Input gamma and output gamma both
default to 2.2. If they are both set to the same value, there is no effect on the image.
3.7.

Geometry

This menu contains adjustments associated with setting up position, aspect ratio and scale of the input
signal. Scale can be as simple as an overscan up to arbitrarily warping the image.
3.7.1.

Horizontal/Vertical Position

Settings: in steps of 1 pixel/line
Change the positional values to match the display boarders.
3.7.2.

Edge Control

Submenu for changing the position of the image edges, effectively scaling the image in horizontal and
vertical direction. HQView-310 and 320 have some limitations compared to HQView-300 regarding
value range, due to the use of the warp engine for scaling and auto zoom.
3.7.3.

Warp

Submenu for warping the image and defining projection condition. The projection condition can be Front
Table top, Front Ceiling, Rear Table top or Rear Ceiling. The corresponding image flip is applied on top
of the following warp applications.
The warp applications are Keystone, 4-Corner, Rotation, and PC. Special portrait warp applications for
clockwise (90°) and counter-clockwise (270°) rotation with scaling are provided as well.
Under the Keystone application the image can be adjusted to match a horizontally and vertically tilted
screen. Also, Pin/Barrel distortion of the lens or screen can be adjusted simultaneously.
Under the 4-Corner application all corners can be moved and the image is calculated to fit into the given
trapezoid.
The Rotation application let you rotate the image from -180 to 180 degree (one full circle). At the same
time Pin/Barrel distortion of the lens or screen can be adjusted again.
Predefined warp maps for portrait mode applications are provided. A 9:16 input image area is rotated
and scaled such that is fills a 16:9 screen.
With PC application activated the HQView-320 communicates with the PC tool Warp Generator. Warp
Generator allows you to define an arbitrary screen in live operation by projecting a grid on the surface
and move the grid points to get a rectangular output. This grid information can then be downloaded in
one of eight slots used for real-time processing of image data which make the image appear rectangular
on a curved screen
The warp generator software allows rotation, scaling and warping simultaneouasly..
For convenience all settings can be reset with one button provided in the submenus.
3.7.4.

Picture Format

Available Settings: Standard, Full Screen, Crop, Anamorphic
Picture Format allows a user to select the displayed aspect ratio where the signal input is at variance
with the display panel's natural aspect ratio.
©
Calibre UK Limited Issue 2.40
nd
22
April 2013
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hqview325Hqview-300 seriesHqview-300sHqview-310

Table of Contents