Defect ID: DEFECT000284653
Summary: Not able to set Extended IP ACL Protocol field to ESP(50) from SNMP
Symptom: Customer was trying to implement ACL to RX from INM but failed.
Using CLI command the access list is added without any problem
access-list 105 permit esp host 1.1.1.1 host 2.2.2.2
Probability: High
Feature: SNMP Management
Reported In Release: RX 02.7.02
Defect ID: DEFECT000286364
Summary: Change gig auto negotiation behavior.
Symptom: Currently, between two gig fiber interfaces, when one side is configured with gig-default auto
(default), the other side is gig-default neg-off, links show up at both sides. Default behavior will
change to the side with neg-off configured shows link up and the side with auto configured shows link
down. In addition: gig-default auto-full is added to switch back to the current behavior (none-default
behavior after the code change).
Probability: Medium
Feature: SYSTEM
Reported In Release: RX 02.7.02
Defect ID: DEFECT000287890
Summary: BGP "allowas-in" does not with confederation config
Symptom: BGP Routes received from peer with local AS (in as-path) are dropped even though "allowas-in" is
used for that particular peer. We have observed this issue only when confederation is configured.
Without confederation it works fine.
Probability: High
Feature: BGP
Reported In Release: RX 02.7.00
Defect ID: DEFECT000288254
Summary: Under "ipv6 router ospf", the "in" parameter after a "distribute-list prefix-list" isn't saved to the
running config.
Symptom: Under "ipv6 router ospf", the "in" parameter after a "distribute-list prefix-list" isn't saved to the
running config even though it is required when entering a "distribute-list prefix-list". As a result, the
config is lost when the write mem command is issued and the device is reloaded.
Probability: High
Feature: OSPFv3
Reported In Release: RX 02.7.02
Defect ID: DEFECT000288573
Summary: LAG port name was only displayed up to 9 characters.
Symptom: LAG port names are being cutoff in the show lag output.
Probability: Medium
Feature: Character I/O
Reported In Release: RX 02.7.02

IronWare Software Release 02.7.03a for Brocade BigIron RX Series Swtches

Release Notes v 1.0
Technical Severity: Medium
Function: IP Mib
Service Request ID: 241185
Technical Severity: Medium
Function: OPTICS
Service Request ID: 242203
Technical Severity: Medium
Function: BGPv4
Technical Severity: High
Function: CONFIGURATION
Service Request ID: 245558
Technical Severity: Medium
Function: Character Handling
Service Request ID: 244909