Installing QSFP cables (optional)

Use this procedure to remove and replace a QSFP cable.
NOTE
The QSFP ports can be used only with an inter-chassis link (ICL) license. After the addition or removal of a license, the
license enforcement is performed on the ports only when the portdisable and portenable commands are issued on
the ports. An ICL license must be installed on all Brocade Backbones forming the ICL connection. Up to six neighboring
Brocade 8510 series chassis can be combined with the QSFP cables.
NOTE
For the Brocade 8510 Backbones, an off-the-shelf QSFP cable up to 50 meters long can be used as an ICL cable.
ATTENTION
For the 8510 series models, if the QSFP cables are not used, make sure the rubber gaskets are in the QSFP
transceivers.
The following table describes the connector port LED patterns and the recommended actions for those patterns.
TABLE 2
QSFP connector port LEDs
LED purpose
Color
QSFP
No light (LED is off)
connector
status
Steady amber
Blinking amber
Steady green
Follow this procedure to install the QSFP cables. Refer to the Fabric OS Administrator's Guide for the configuration
procedure and requirements.
The figure below shows an QSFP cable and transceiver. The QSFP connectors on the core blades are labeled by
trunk group (trunking is optional) for ease of installation. The subsequent figures shows acceptable cabling
configurations for the ICL feature. The recommended topology is the parallel type where there are four QSFP cables
connected between any pair of Brocade 8510 series chassis.The full mesh configuration is also supported.
Brocade DCX 8510-8 Backbone QuickStart Guide
53-1002366-01
Status
Recommended action
No QSFP module, all four
No action required if QSFP no
QSFP ports are disabled
present or
verify that the QSFP is fully inserted.
QSFP module is in, all four
No action required if QSFP only is
ports have no signal/no
installed or
sync.
ensure that the cable is properly
connected. If the LED remains
amber, consult the Brocade DCX
8510-8 supplier.
Port is disabled or faulted,
Check for console messages or wait
FC link activity, segmented,
for all four ports to come online.
loopback mode, also
during transition between
QSFP cable insertion and
confirmation.
Both ends of QSFP cable
No action required.
are in and all ports are
online. Full link is
established.