Dell PowerVault 100T User Manual page 55

Lto series
Hide thumbs Also See for PowerVault 100T:
Table of Contents

Advertisement

Table 5-5. TapeAlert Flags and Descriptions (continued)
30
1Eh
31
1Fh
32
20h
33
21h
34
22h
36
24h
37
25h
39
27h
51
33h
TapeAlert Flags Supported by the Tape Drive
Hardware A
Set when a hardware failure
occurs that requires that you
reset the tape drive to
recover.
Hardware B
Set when the tape drive fails
its internal self tests.
Interface
Set when the tape drive
detects a problem with the
SCSI or LDI (RS-422)
interface.
Eject media
Set when a failure occurs that
requires you to unload the
cartridge from the drive.
Download fail
Set when a field microcode
replacement (FMR) image is
unsuccessfully downloaded
to the tape drive via the SAS
interface.
Drive temperature
Set when the drive's
temperature sensor indicates
that the drive's temperature
is exceeding the
recommended temperature of
the system (see Chapter 6,
"Specifications," on page
6-1).
Drive voltage
Set when the drive detects
that the externally supplied
voltages are either
approaching the specified
voltage limits or are outside
the voltage limits (see
Chapter 6, "Specifications,"
on page 6-1).
Diagnostics required
Set when the drive detects a
failure that requires
diagnostics to isolate the
problem.
Tape directory invalid
Set when the tape directory
at unload
on the tape cartridge that
was previously unloaded is
corrupted. The file-search
performance is degraded.
If resetting the drive does not
recover the error, use the
error code from the
single-character display,
library user interface, or SCSI
drive sense data. See
"Descriptions and Corrective
Actions" on page 5-10.
Use the error code on the
single-character display,
library user interface, or SCSI
drive sense data. See
"Descriptions and Corrective
Actions" on page 5-10.
Locate error code 8 or 9 in
"Descriptions and Corrective
Actions" on page 5-10.
Unload and reload the tape
cartridge.
Ensure that it is the correct
image. Download the FMR
image again.
See error code 1 in
"Descriptions and Corrective
Actions" on page 5-10.
See error code 2 in
"Descriptions and Corrective
Actions" on page 5-10.
See error code 6 in
"Descriptions and Corrective
Actions" on page 5-10.
Rebuild the tape directory by
reading all the data.
Chapter 5. Troubleshooting
5-19

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents