2-16. Power Supply Information

Output Voltage Regulation, Ripple, and Noise
Output Voltage Limits (Vdc)
Output
Min
1
4.75V
2
11.40V
3
-4.50V
4
-10.92V
Output Current Capacity
Output Nom (Vdc) Max (A) Min (A)
1
5.0V
2
12.0V
3
-5.0V
4
-12.0V
Input Voltage
Range
Min (V) Nom (V)
Range 1
90
Range 2
180
Safety
The power system meets all applicable clauses for UL 1950 2nd edition with-
out D3 deviations. The power system passes all tests for CUL and TUV
safety.
EMI
The power system, operating with resistive load, meets FCC class B and
CISPR 22 class B conducted limits.
32
AR1000 RAID Subsystem Hardware Reference Guide
IV. Hardware Setup
Nom
Max
5.00V
5.25V
12.00V
12.60V
-5.00V
-5.50V
-12.00V
-13.20V
40.0
3.0
12.0
1.5
0.5
0.0
0.5
0.0
Max (V)
115
132
230
264
Ripple/Noise
Maximum
50mV
p-p
120mV
p-p
120mV
p-p
120mV
p-p