Figure 4.5
(2)
Servo burst capture circuit
The four servo signals can be synchronously detected by the STROB signal, full-wave
rectified integrated.
(3)
A/D converter (ADC)
The A/D converter (ADC) receives the servo signals are integrated, converts them to digital,
and transfers the digital signal to the DSP unit.
4 - 16
Physical sector servo configuration on disk surface
C141-E077-01EN
Servo frame