Vibration
a. Operating—normal
The drive as installed for normal operation, shall comply with the complete specified performance while
subjected to continuous vibration not exceeding
5 - 500 Hz, swept sine: 0.5 G (zero to peak)
10 - 500 Hz, random: 0.00051 G
Vibration may be applied in the X, Y, or Z axis.
b. Operating—abnormal
Equipment as installed for normal operation shall not incur physical damage while subjected to periodic
vibration not exceeding:
15 minutes of duration at major resonant frequency
5 - 500 Hz, swept sine: 0.75 G (zero to peak)
10 - 500 Hz, random: 0.00029 G
Vibration occurring at these levels may degrade operational performance during the abnormal vibration
period. Specified operational performance will continue when normal operating vibration levels are
resumed. This assumes system recovery routines are available.