Conducted Noise Immunity; Power Sequencing - Seagate ST300MP0004 Product Manual

Savvio 15k.3 sas product manual
Hide thumbs Also See for ST300MP0004:
Table of Contents

Advertisement

General DC power requirement notes.
1. Minimum current loading for each supply voltage is not less than 1.7% of the maximum operating current
shown.
2. The +5V and +12V supplies should employ separate ground returns.
3. Where power is provided to multiple drives from a common supply, careful consideration for individual
drive power requirements should be noted. Where multiple units are powered on simultaneously, the peak
starting current must be available to each device.
4. Parameters, other than spindle start, are measured after a 10-minute warm up.
5. No terminator power.
7.3.1

Conducted noise immunity

Noise is specified as a periodic and random distribution of frequencies covering a defined frequency range.
Maximum allowed noise values given below are peak-to-peak measurements and apply at the drive power
connector.
+5V
=
250 mV pp from 100 Hz to 20 MHz.
+12V
=
450 mV pp from 100 Hz to 100 KHz.
250 mV pp from 100 KHz to 20 MHz.
150 mV pp from 20 MHz to 100 MHz.
7.3.2

Power sequencing

The drive does not require power sequencing. The drive protects against inadvertent writing during power-up
and down.
26
Savvio 15K.3 SAS Product Manual, Rev. E

Advertisement

Table of Contents
loading

Table of Contents