In case you select No in response to a rebuild prompt,
select Scan Devices from the File menu of the Status
window to trigger a new prompt. If a power failure in-
terrupts a rebuild, the daemon will restart the rebuild
process.
To configure a rebuild
1. Select Specify Policy under the Edit menu of the
Status window.
2. Select one of the following policy options:
• The Manual rebuild radio button requires a user to
manually initiate a rebuild of the volume.
• The Automatic rebuild option forces the daemon to
initiate the rebuild process automatically and mini-
mize the possibility of data loss.
3. If you select the automatic rebuild option you have
the following choices within the Automatic Rebuild
Options frame.
• The daemon can be configured to perform an Im-
mediate Rebuild following detection of an offline
hard disk drive.
• The Rebuild Only If Needed option will delay the
rebuild for a Safe volume with an offline hard disk
drive until the write occurs to the Safe volume.
4. Click the Accept button to commit the selected op-
tions.
The daemon uses the specified rebuild policy to
maintain redundancy. The Status window displays a re-
build in progress.