3. Wrap the motor with plastic wrap to prevent water from entering it. Spray degreaser or
detergent on the blower wheel and the blower housing. Allow it to soak for five minutes. Rinse
the wheel and housing with hot tap water, then dry with a clean cloth.
Wrap the motor and wires
with plastic wrap or a
4. Remove the plastic wrap from the blower motor assembly. Reassemble the blower motor
assembly and blower housing. Reinstall the blower shield.
5. Reinstall the blower assembly in the fryer and reconnect the wiring disconnected in Step 1.
6. Light the fryer in accordance with the procedure described in Chapter 3, Section 3.1.2 of the
BIPH52/55-MPH52/55 Series Gas Fryer Installation and Operation Manual (P/N 819-6087).
Remove these screws to
remove the shield from the
blower assembly.
plastic bag.
Blower Wheel
1-12
Remove these nuts to
separate the blower
motor from the housing.
Blower Housing