Flow Chart Of Troubleshooting; Baseband; Power On - Samsung SGH-X630 Service Manual

Gsm telephone
Hide thumbs Also See for SGH-X630:
Table of Contents

Advertisement

10. Flow Chart of Troubleshooting

10-1.Baseband

10-1-1. Power ON

'Power ON' Does not work
Check the current consumption
Current consumption
≥ 100mA ?
Check the V bat. voltage
Voltage ≥ 3.3V ?
Check the pins of U102
C119 ≥ 1.8V ?
C116 and C121 = 2.8V?
Check the clock signal
at pin #1 of OSC700
Freq.=13MHz,Vrms ≥ 300mV
Check the Initial operation
This Document can not be used without Samsung's authorization
YES
YES
YES
YES
YES
END
SAMSUNG Proprietary-Contents may change without notice
NO
NO
NO
NO
C113=1.5V?
YES
NO
10-1
Down load again
Charge the Battery
Check U102 and C119
NO
Check U102 and C113
Check the clock generation
circuit (OSC700, U104 pin#4)

Advertisement

Table of Contents
loading

Table of Contents