5. Flow Chart of Troubleshooting and Circuit Diagram
5-1 Power ON
5-1
Downloaded from
www.Manualslib.com
'POWER ON'does not work
Yes
Check the Battery Voltage
is more than 3.4V?
Yes
The node
between D101 and C106 > 2.8 V ?
Yes
When the "END" key is pressed,
D100 pin1 > 3.4V ?
Yes
U111, U112 pin5 = 2.5V ?
Yes
Check for the clock signal at R609
Yes
Check the initial operation
END
manuals search engine
No
Charge the Battery
No
Check U100 and the path from +VBATT
to C106
No
Replace the PBA
No
Check U111, U112 and related circuit
No
Check the clock generation circuit
(related to U502 and U601)