7. SGH-E700 Flow Chart of Troubleshooting
1. Power On
' Power On ' does not work
Check the Battery Voltage
is more than 3.4V
C414(V_ISUP) = 2.7V?
Check the Clock at
R401=32KHZ
C431 (VDD1) = "H"?
C430(VDD2) & C429(VDD3)
Check for the clock at C133
Check the initial operation
Yes
Yes
Yes
Yes
Yes
= 2.8V?
Yes
= 13MHz
Yes
Yes
END
SAMSUNG Proprietary-Contents may change without notice
This Document can not be used without Samsung's authorization
No
Change the Battery
No
Check the PMU related to V_ISUP
No
Resolder OSC400
No
Check the VDD1 circuit
No
Check the VDD2,VDD3 circuit
No
Check the clock generation circuit
(related to OSC101)
1