HSU09/12XCK-SM Table of Contents 2. Introduction 2.1 Safety Cautions Be sure to read the following safety cautions before conducting repair work. The caution items are classified into “Warning” and “Caution”. The “Warning” items are especially important since they can lead to death or serious injury if they are not followed closely. The “Caution” items can also lead to serious accidents under some conditions if they are not followed.
HSU09/12XCK-SM Introduction Warning Do not repair the electrical components with wet hands. Working on the equipment with wet hands can cause an electrical shock. Do not clean the air conditioner by splashing water. Washing the unit with water can cause an electrical shock.
Page 6
HSU09/12XCK-SM Introduction Warning Be sure to use an exclusive power circuit for the equipment, and follow the technical standards related to the electrical equipment, the internal wiring regulations and the instruction manual for installation when conducting electrical work. Insufficient power circuit capacity and improper electrical work can cause an electrical shock or fire. Be sure to use the specified cable to connect between the indoor and outdoor units.
HSU09/12XCK-SM Introduction 2.1.3 Inspection after Repair Warning Check to make sure that the power cable plug is not dirty or loose, then insert the plug into a power outlet all the way. If the plug has dust or loose connection, it can cause an electrical shock or fire. If the power cable and lead wires have scratches or deteriorated, be sure to replace them.
HSU09/12XCK-SM Introduction 2.1.4 Using Icons Icons are used to attract the attention of the reader to specific information. The meaning of each icon is described in the table below: 2.1.5 Using Icons List Icon Type of Information Description A “note” provides information that is not indispensable, but may Note: Note nevertheless be valuable to the reader, such as tips and tricks.
HSU09/12XCK-SM HSU12XCK HSU09XCK Model Cooling Cooling 2.64 3.51 12000 Btu/h Capacity Rated 9000 3023 kcl/h 2267 POWER SUPP LY NOMINAL Phase DISTRIBUTION Frequency SYSTEM VO LTAGE Voltage 115V Moisture Removal 7.09 Running Current(Rated) Power Consumption Rated 1080 EER Rated Liquid 6.35...
Page 10
HSU09/12XCK-SM Outdoor Unit HSU09XCK HSU12XCK Casing Color lvory white Type Hermetic motor compressor Rotary Model Motor Output 1125 Compressor Oil Type NMOC Ze-Gles RB68EP or equivalent 0.32 Oil Charge 0.37 R410A R410A Model Refrigerant Charge m³/min 33.3 26.7 Air Flow Rate (H/L) 941.3...
HSU09/12XCK-SM Connector Wiring Diagram 4.Printed Circuit Board Connector Wiring Diagram 4.1 Indoor unit Connectors Indoor PCB 1)CN1connector for transformer. 2)CN2 connector for power line. 3)CN3 connector for transformer. 4)CN5” connector for up and down step motor. 5)CN6 connector for ambient temp. sensor and piping temp.sensor. 6)CN7 connector for receiver display.
HSU09/12XCK-SM Functions and Control 5 Functions and control 5.1 main functions and control specifications Including brief introduction to air conditioners of series models and electric control function. 5.1.1 Automatic running Single cold automatic run mode: After entering into this mode, the main control “MCU” determines the corresponding work pattern according to the indoor temperature so as to maintain the preset temperature (the preset temperature is 78°F).
Page 13
HSU09/12XCK-SM Functions and Control Avoiding electrical shock: outlet air is available 2 seconds later after startup. High temperature expiration protection: (1)High temperature expiration prevention:When the temp.of coil pipe is above 161°F,compressor and outlet air stop running 10 seconds later, and inlet air runs as the temp. sensor is off. When compressor stands by for 3 minute and the temp.
Page 14
HSU09/12XCK-SM Functions and Control After another hour the temp. setting increase by more 1°F and then run continuously for another 6 hours and then close. 5.1.6.2 In heating mode, the temp. setting decrease 3°F one hour after start up. After another hour the temp.
HSU09/12XCK-SM Functions and Control to enter additional options when cycle dispay to will flash and then press quickly press and then press rapidly 10 times within 6 seconds, and the auto recovery function of power on can be set on/off. If the buzzer rings 4 times, the the auto recovery function of power on is available;...
HSU09/12XCK-SM 6. System Configuration 6.1 System Configuration After the installation and test operation of the room air conditioner have been completed, it should be operated and handled as described below. Every user would like to know the correct method of operation of the room air conditioner, to check if it is capable of cooling (or heating) well, and to know a clever method of using it.In order to meet this expectation of the users, giving sufficient explanations taking enough time can be said to reduce about 80% of the requests for servicing.
HSU09/12XCK-SM Parts and Functions Indoor Unit Remote controller 7.TEMP display Additional functions display Operation mode QUITE SLEEP HEALTH POWER Remote controller 9. QUIET button 10. COOL button 11. AUTO button 12. FAN button 13. TIMER button 14. HEALTH button 15. LOCK button Used to lock buttons and LCD display 16.
HSU09/12XCK-SM Operation Base Operation Emergency operation and test operation Emergency Operation: Use this operation only when the remote controller is defective or lost, and with function of emergency running, air conditoner Remote controller can run automatically for a while. When the emergency operation switch is pressed, the unit beeps once, which means the start of this operation.
HSU09/12XCK-SM Operation Sleep Operation 4.Set the wind speed change when sleeping If the wind speed is high or middle before setting for the Press button to enter additional options, when sleep, set for lowing the wind speed after sleeping. cycle display to will flash.
HSU09/12XCK-SM Operation Timer On/Off On-Off Operation Healthy airflow Operation 1.After unit starts, select your desired operation mode. 1.Press to starting Setting the comfort work conditions. 2.Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows: 2.The setting of healthy airflow function Remote controller: Press...
HSU09/12XCK-SM Maintenance For Smart Use of The Air Conditioner Remote Controller Indoor Body Setting of proper room Do not block the air inlet temperature or outlet Proper wipe the air conditioner by using a temperature soft and dry cloth.For serious stains, use a neutral detergent diluted with Do not usewater,wipe the controller water.Wring the water out of the...
Page 29
HSU09/12XCK-SM Table of Contents Cautions WARNING This system should be installed by a qualified HVAC professional. Do not attempt to install the air conditioner by yourself because improper works may cause fire, water leakage, personal injury or cleath. WARNING Check proper When abnormality such as burnt-small found, Use an exclusive immediately stop the operation button and...
HSU09/12XCK-SM Trouble shooting Cautions Before asking for service, check the following Do not obstruct or cover the ventilation grille of the air first. or any other things into the conditoner.Do not put fingers inlet/outlet and swing louver. Cause or check points Phenomenon Do not allow children to play with the air conditioner .In no...
HSU09/12XCK-SM Codes and Description 7.Codes and Description 7.1.Problem Symptoms and Measures Symptom Check Item Details of Measure Check to make sure that the rated voltage is Check the power supply. supplied. None of the units Check to make sure that the indoor PCB is operates Check the indoor PCB broken...
HSU09/12XCK-SM Codes and Description 7.2 Error Codes and Description indoor display Code indication Reference Description Page indoor Room temperature sensor failure u l i Indoor Malfunction The code indication that is listed above is the main fault Troubleshooting Caution Be sure to turn off power switch before connect or disconnect connector, or else parts damage may be occurred.
Page 33
HSU09/12XCK-SM Codes and Description E4 Indoor EEPROM error: Replace the PCB of indoor unit E14 :Indoor fan motor malfunction Notes: When the unit is on ,don’t pull out or insert the terminal of the motor (CN9), or else The motor would be damaged. whether terminal CN8 Pull out and reinsert the terminals and CN9 on indoor PCB...
HSU09/12XCK-SM 9.Installation Preparation Selection of Installation Place Necessary Tools for Installation Indoor Unit - Select a location that is ● Torque wrench ● Hammer (17mm,22mm,26mm) ● Nipper ● Robust not causing vibration, where the body can be supported sufficiently. ● Hacksaw ●...
HSU09/12XCK-SM · [ Left Left-rear piping ] Accessory parts ● In case of left side piping, cut away, with a nipper, the lid for left piping. In case of left-rear piping, bend the pipes according to the piping direction to ●...
Use lock nuts to secure conduit tubes. Outdoor unit HSU09XCK-W Power cable: 2wire with ground 14AWG HSU12XCK-W Power cable: 2wire with ground 14AWG 1. If the fuse on PC board is broken please change it with the type of T. 3.15A/250V(indoor unit),25A/250V(outdoor unit).
Page 41
HSU09/12XCK-SM No gas leakage? On Drainage In case of gas leakage, tighten parts of pipe connection. If leakage stops, ● then proceed step 6. If leak continues, remove the refrigerant used for the Please install the drain hose so as to be downward slope without fail. ●...