Cross Flow Fan And Indoor Fan Motor Removal Procedures - Panasonic CS-E18CKE Service Manual

Table of Contents

Advertisement

12.5. Cross Flow Fan and Indoor Fan Motor Removal Procedures

1. In order to remove the Cross Flow Fan and Indoor Fan
Motor, Control Board need to be taken out by releasing all
the connectors as indicated below.
a. Release the Earth Wire screw. (Fig. 5)
b. Release the Intake Air Sensor. (Fig. 5)
c. Release the Piping Sensor. (Fig. 5)
d. Release the CN-REC connectors. (Fig. 5)
e. Release the CN-STM1. (Fig. 5)
f. Release the CN-STM2. (Fig. 5)
g. Release connectors generator Ionizer. (Fig. 5)
2. Pull out the Drain Hose from outlet to remove the Discharge
Grille. (Fig. 6)
3. Removing the right and left screws. (Fig. 7)
4. By pressing down the hook at the left and pushing up the
hook at the right, you will be able to remove the Control
Board. (Fig. 7)
5. Remove the screw at the Cross Flow Fan. (Fig. 8)
78
Fig. 5
Fig. 6
Fig. 7
Fig. 8