Values of T1, T2, and T3 depend on remote control setting temperature, as shown in below table. After the adjustment of T1, T2
and T3 values, the operation mode for that particular environment and remote control setting is judged and performed, based on
the above operation mode chart, every 30 minutes.
Remote Control Setting Temperature (°C)
There is a temperature shifting on T1, T2, and T3 if the operation mode judged is changed from Cooling/Soft Dry to Heating or vice
verse.
Operation Mode change from
Cooling/Soft Dry → Heating
Heating → Cooling/Soft Dry
Example of operation mode chart adjustment:
From the above table, if remote control setting temperature = 25,
T1 = 25 + 7 = 32; T2 = 25 + 6 = 31; T3 = 25 - 7 = 18
The operation mode chart for this example is as shown in below figure and the operation mode to be performed will depend on
indoor intake air temperature and outdoor air temperature at the time when the judgment is made.
8.1.7.

Indoor Fan Motor Operation

A. Basic Rotation Speed (rpm)
• Required rotation speed for fan is set to respond to the remote control setting (10 rpm unit)
[Cooling, Dry, Fan]
Remote Control
Tab (rpm)
SHI
E18CK
1530
E21CK
1610
[Heating]
Remote Control
Tab (rpm)
SSHI
E18CK
1590
E21CK
1640
16 ~ 18
19 ~ 22
23 ~ 26
27 ~ 30
O
O
Hi
Me+
1440
1360
1520
1420
O
O
SHi
Me+
1560
1480
1610
1520
T1
+10
+8
+7
+6
Temperature shifts (°C)
O
O
O
Me
Me-
Lo
1290
1220
1150
1330
1240
1150
O
O
O
Me
Me-
Lo
1410
1340
1270
1440
1350
1270
19
T2
T3
+8
-5
+7
-7
+6
-7
+5
-8
-2
+2
Lo-
SLo
SSLo
850
760
890
800
Lo-
SLo
SSLo
850
400
890
400
630
630
300
300