2.1

GENERAL

This section provides information and procedures for powering up the unit.
2.2

CONTROL DIP SWITCHES

A four position DIP switch on the rear panel provides manual control and setup selection. Mode
setting is as follows: (In setting the DIP switches, "D" = down and "U" = up, "X" = don't care
for this function).
Mode
1 2 3 4
U X X X
D X X X
X U X X
X D X X
X X U X
X X D X
X X X U
X X X D
Set the switches to the settings appropriate for your system.
* The receiver must be set to the same format (NTSC or PAL) as the desired channel being
received. The receiver will not operate correctly with incompatible settings.
2.3

FRONT PANEL CONTROLS AND INDICATORS

The front panel indicators and controls are shown in
and described in
Table 4
SECTION 2

POWER ON PROCEDURES

Table 4. Control DIP Switch Functions

Setup Functions
NTSC Video System*
PAL Video System*
Modulator Channel 3 (MODEL SPECIFIC)
Modulator Channel 2 (MODEL SPECIFIC)
Normal video
Color Bars, Tones
LNB Power OFF
LNB Power ON