Vax V-120 User Guide.qxd
www.vax.co.uk
Fig.6/6
Rinse nozzle under running water. Remove debris from
squeegee (A) and wipe with a damp cloth (Fig.6/7).
Fig.6/7
To replace nozzle, make sure latches are out. With the
cleaner in the upright position, align middle section of
nozzle with opening on cleaner and slide latches inward as
described in Section 3.
Cleaning the Brushes
The brush assembly can be removed for easy cleaning.
Turn cleaner OFF and disconnect from electrical outlet.
Place handle in the upright position. Remove tanks to
prevent leaking. Set aside.
Pull the two nozzle release buttons out and remove nozzle
as Fig.6/3. Tilt cleaner back so handle rests on floor.
Push two brush release buttons (A) and remove the brush
assembly (Fig.6/8).
A
Fig.6/8
10
maintenance
9/10/07
12:43
Page 10
The brushes can be washed with a mild detergent and
rinsed. Do not use a solvent based detergent.
To replace brushes, align post (A) on brush block with hole
(B) on bottom of cleaner. Turn brushes slightly until post
fits easily into hole. Press brush assembly firmly to snap
into place (Fig.6/9).
Fig.6/9
Return cleaner to upright position. Replace nozzle, making
sure latches (E) are out (Fig.6/10).
A
Fig.6/10
Align middle section of nozzle with opening on cleaner.
While holding nozzle in place, slide latches inward to lock in
place. Replace tanks.
B
A
A
A