Dimensions and features
Indoor unit dimensions
Model
VA6-020 MXNHI
VA6-025 MXNHI
VA6-035 MXNHI
Model
VA6 – 035 MXNHKI
VA6 – 050 MXNHKI
Model
VA6 – 035 MXNHDI
VA6 – 050 MXNHDI
Outdoor unit dimensions
Model
VA6 – 050 MXNHO
VA6 – 085 MXNHO
VA6 – 105 MXNHO
All climaVAIR V-Multi units have the following features
4 Modes
Cooling, heating, fan and dry mode.
Auto operation
Automatic activation in the appropriate
mode (COOL - HEAT - DRY), by adjusting
its operation to the ambient temperature.
The user can also select the desired airflow.
Ionizer (wall mount only)
Negative ion generator which as well as being
beneficial for well-being and the environment,
also neutralises odours, provides freshness
and reduces contamination.
Infra-red remote control
All functions controlled by infra-red
remote control.
Hot start function
Only starts the internal fan when the heating
coil is hot to prevent cool air discharge.
Single phase supply
All climaVAIR multi units operate on a single
phase supply.
H
L
D
Kg
285
760
182
8.5
285
760
182
8.5
285
760
182
8.5
H
L
D
Kg
260
570
570
17
260
580
580
17
H
L
D
Kg
290
610
550
14
290
1090
500
25
H
L
D
Kg
928
680
288
54
840
1068
340
74
840
1068
340
74
Auto restart function
After power cut this function ensures the
system restarts with the same settings (as those
in force prior to power supply interruption).
Silent operation
Lowers the internal fan speed to provide
reduced noise levels.
Turbo
Increases the air conditioning speed when
faster room cooling/heating is required.
Horizontal air swing
(Cassette and high wall only) Enables the air
direction to be adjusted horizontally for
improved distribution.
Vertical air swing
(High wall units only) Enables the air
direction to be adjusted vertically for
improved distribution.
Sleep function
Function which adapts the ambient
temperature during sleep.
24hr programmer
Programs the units so that they start
or stop at user defined times.
LR
Outdoor valve protector
Protects the valves on the outdoor unit
from exposure to the elements.
Energy class 'A'
Many unit combinations achieve 'A' rated
energy efficiency.
Defrost
Prevents the outdoor unit from freezing
in the winter months.
Anti-rust outdoor
Outdoor unit made of galvanised steel and
anti-rust materials. Even resistant in
environments with high saline content.
DC inverter technology
Technology which provides energy saving in
comparison to conventional on/off systems.
R410a
Energy efficient zero ozone depleting
potential (ODP) refrigerant.
Twin rotary
Twin rotating cylinders provide improved
efficiency and reduced vibration in
comparison with single types.