B. AC Current (main display) + AC Voltage
(secondary display) Measurement (see figure 5)
Figure 5
16
Model UT232: OPERATING MANUAL
The AC current ranges are: 40A, 100A, 400A and 1000A
The AC Voltage ranges are: 15V, 100V, 300V and 600V
To measure AC current + AC voltage, connect the Meter
as follows:
1.
Press the MENU to select AC Current (main display)
+ AC Voltage (secondary display) range.
Press the lever to open the transformer jaw.
2.
Center the conductor within the transformer jaw,
3.
then release the Meter slowly until the trasnformer
jaw is completely closed, Make sure the conductor
to be tested is placed at the center of the transformer
jaw, otherwise it will casue deviation. The Meter
can only measure one conductor at a time, to
meausre more than one condutor at a time will
cause deviation.
The double display shows the AC current True
4.
RMS value and AC voltage True RMS value.
5.
Press MAX/ , the LCD displays MAX, it starts
recording the maximum AC current True RMS value.
Press MAX/
again to show the present AC