11. Remove collection chambers and set drain lines back onto their
respective evaporator plates. Be sure to push the drain line into
it's anchor.
12. Reinstall the lower panel. Do not overtighten panel screws.
13. Move unit back into position and re-connect power. Allow unit
to stabilize for 12 hours before reintroducing product.

Condenser Cleaning

Interval - Every Three Months
To maintain operational efficiency, keep the front grille free of dust
and lint, and clean the condenser every three months. Depending
on environmental conditions, more or less frequent cleaning may
be necessary.
WARNING
Disconnect electric power to the unit before cleaning
the condenser.
IMPORTANT
IMPORTANT
DO NOT use any type of cleaner on the condenser unit.
14. Remove the grill. (See MAINTENANCE)
15. Clean the condenser coil using a using a soft brush or vacuum
cleaner.
16. Install the grill. (See MAINTENANCE)
Condenser
U-Line 3000 Series Cleaning
Storage, Vacation and Moving
If not using the unit for an extended period, or otherwise stored,
follow these steps completely:
WARNING
Electrical Shock Hazard. Disconnect power before
servicing. Before operating, replace all panels. Failure
to do so may result in electrical shock or death.
IMPORTANT
IMPORTANT
If the ambient temperature is expected to drop below
50°F, turn off and unplug unit.
1. Remove all consumable contents from the unit.
2. Disconnect the power cord from its outlet, and leave it
disconnected until the unit is returned to service.
3. Clean and dry the interior of the cabinet.
4. During periods of nonuse, the cabinet must remain open to
prevent formation of mold and mildew. Open door a minimum
of 2 in. (5 cm) to provide the necessary ventilation.

Product Disposal

DANGER
RISK OF CHILD ENTRAPEMENT. Before you throw away
your old refrigerator or freezer, take off the doors and leave
shelves in place so children may not easily climb inside.
If the unit is being removed from service for disposal, check and
obey all Federal, State and Local regulations regarding the disposal
and recycling of refrigeration appliances, and follow these steps
completely:
1. Remove all consumable contents from the unit.
2. Disconnect power to the unit's power receptacle. Unplug the
power cord from its outlet.
3. Remove the cabinet door.
16