AXIS 233D - Dome Configuration
34

Guard Tour

A guard tour displays preset positions, one-by-one, in a pre-determined order or at
random, and for configurable time periods. Once a preset position has been set and added
to the guard tour, the following settings can be made:
• Move Speed - sets the speed of the Pan/Tilt movements to the preset position.
• View Time in seconds or minutes.
• View Order (or Random).

OSDI Zones

On-screen Direction Indicator (OSDI) Zones can be included in the overlay text to aid the
user to navigate the camera. Each OSDI Zone is set up with coordinates and a descriptive
name.
The camera uses the coordinates of the center of the image to set the lower left and upper
right zone areas. First navigate to where you would like the lowermost left point of the
OSDI Zone to be located. By clicking the Get button the coordinates are set. Proceed to
where the upper right point of the zone should be located and click its Get button. Give the
zone a descriptive name and click Ok. See Overlay Settings, on page 19, for information
about including the name of the OSDI Zone in the overlay text.

Advanced

Limits
Define the pan, tilt, zoom and focus limits for the AXIS 233D. Movements to the left and
right, up and down, can be restricted to narrow the area under surveillance. The near focus
limit can be set to avoid focusing on objects too close to the camera.
Note:
Once a limit has been saved, this position cannot be exceeded by the AXIS 233D unless the values have
been reset and saved to a greater value first (reset the default values of the mechanical restrictions).
Move speed sets the speed of the camera's Pan/Tilt movements. The default setting is
maximum speed.
Controls
Shortcut command buttons can be created to provide direct access to various commands
provided by the AXIS 233D. The buttons are then displayed in the PTZ Panel which is
available on the Live View page by clicking Ctrl Panel (see page 10). Axis' VAPIX® API
allows you to create your own commands. For more information go to www.axis.com

Control Queue

The administrator can set up a queue for the PTZ controllers. Once set up, the PTZ Control
Queue buttons appear on the Live View page offering one viewer exclusive control for a
limited amount of time. Other users will be placed in the queue.