3.0 INSTA L L AT I O N
The Patton Model 501LC is easy to install. The following
instructions will clearly explain each step.
1.
Look at your equipment's user manual to determine if the shell
of the DB-25 connector is connected to frame ground of the
equipment.
2.
If there is any doubt that the shell of the connector is
connected to frame ground, you should use the ground strap.
Attach one end of the grounding strap to one of the connectors
on the Model 501LC (see diagra, and the other end to
frame ground.
3.
Securely connect the Model 501LC between the incoming
data cable and your equipment's I/O port. To obtain maximum
protection, install Model 501LC at both ends of your RS-232
cable.
Alternate Ground Connections
M O D E L 5 0 1 LC
ASYNC. DB-25
PROTECTOR
3
SURGE
APPENDIX A
PATTON MODEL 501C SPECIFICATIONS
Case: Molded ABS (black) plastic
Interface: DB-25 to DB-25
Pins Protected: 2-8, 11, 20, 22, 24 & 25, pin 1 ground
External Power: None
Connectors: (2) DB-25s = 1 Male, 1 female
Max Continuous Operating Voltage: +/- 15 Volts
Clamp Voltage: 27 Volts @ 200amps (8/20µs)
Series Resistance: None
Surge Capacity: 1250amps 8/20µs waveform
Capacitance: (line-line or line-ground) 45pf per signal
connection
Operational/Storage Temp: -55 to +100°C
Copyright ©
Patton Electronics Company
All Rights Reserved
4

Advertisement