Changing Brightness/Contrast - DSC PowerSeries PC1404 User Manual

V1.0
Hide thumbs Also See for PowerSeries PC1404:
Table of Contents

Advertisement

[3] Auto-arm Time
The system can be programmed to arm at a programmed time each day. Upon entry of this section,
enter 4 digits for the 24-hour Auto-arm time.
At the selected auto-arm time, the keypad buzzers will sound for a programmed amount of time
(programmable by the installer only) to warn that an auto-arm is in progress. The bell can also be
programmed to squawk once every 10 seconds during this warning period. When the warning
period is complete, the system will arm with no exit delay and in the Away Mode.
Auto-arming can be cancelled or postponed by entering a valid access code only during the pro-
grammed warning period. Auto-arming will be attempted at the same time the next day. When the
auto-arming process is cancelled or postponed, the Auto-arm Cancellation Reporting Code will be
transmitted (if programmed).
If arming is inhibited by one of the following, the Auto-arm Cancellation transmission will be com-
municated.
- AC/DC Inhibit Arm
- Latching System Tampers
- Zone Expander Supervisory Fault
[4] System Test
The system's Bell Output (2 s), Keypad Lights and Communicator are tested. This test will also mea-
sure the panel's standby battery.
[5] Enable DLS / Allow System Service
If enabled, the installer will be able to access Installer Programming by DLS or via the keypad [,][8].
In case of DLS access, this provides a window where rings will be detected by the panel. Depending
on the option programmed, the DLS window will remain open for either 1 or 6 hrs, allowing the
installer to enter DLS one time or an unlimited number of times, respectively. After the 1-hr or 6-hr
window has expired, Installer's Programming will be unavailable again until the window is re-
opened.
[6] User Call-up
If enabled by the Installer, the panel will make 1 attempt to call the downloading computer. The
downloading computer must be waiting for the panel to call before downloading can be performed.
[7] For Future Use
[8] For Future Use

Changing Brightness/Contrast

PK5500 keypads
When this option is selected, the keypad will allow you to scroll through 4 different brightness/con-
trast levels.
1. Press
[Master code].
2. Use the
keys to scroll to either Brightness Control or Contrast Control.
3. Press
to select the setting you want to adjust.
4. a) Brightness Control: Use the
keys to scroll to the desired level.
b) Contrast Control: Use the
keys to scroll to the desired contrast level.
5. To exit, press
.
PK5501/PK5508/PK5516 keypads
When this option is selected, the keypad will allow you to scroll through 4 different backlighting lev-
els. A level of 0 disables the backlighting.
1. Press
[Master Code].
2. Use the
key to move through the 4 different backlighting levels.
3. The level is automatically saved when you press
to exit.