Dimplex CFP3913 Service Manual page 13

Mozart fireplace
Hide thumbs Also See for CFP3913:
Table of Contents

Advertisement

Figure 17
Terminal Block
Black
wire
leading
from
firebox
Blue wire
leading
from
firebox
Cable Clamp
Wire with smooth
edges leads to
8. Use pliers to squeeze the portion of the Cable Clamp
narrow blade of
plug
9. Release the cord from the clamp.
10. Feed replacement Power Cord through the hole in the
Wire with ridges
on edge leads to
wide blade of plug
11. Affix the Cable Clamp to the Power Cord close to the
12. Reattach Access Panel to chassis using the two (2)
13. Follow steps 1 through 3 in reverse order to reassemble
13
screwdriver, release the two (2) black wires from the
Terminal Block (turn the screws of the Terminal Block
counter-clockwise) which lead from the Power Cord.
Take note of their original positions.
(Figure 17) that sits on the inside of the Access Panel
and push cord and clamp through the panel.
Access Panel and connect the two (2) ends of the Power
Cord to the Terminal Block.
The smooth edged side of the Power Cord leads from the
narrow blade of the plug and will connect to the terminal
opposite to the black wire from within the firebox. The
side of the Power Cord with ridges leads from the wide
blade of the plug and connects to the terminal opposite
the blue wire from the firebox.
Access Panel and push clamp and cable through the
Access Panel to secure in place.
screws removed in step 2.
fireplace.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mozart cfp3913

Table of Contents