C. Surface Mounting
A Viking model VE-3x5 can be used to surface mount an E-40 to a wall or post. Drill a small wire exit hole in wall. Pull wire through and seal hole
around wire with putty or caulking. Route wire into the VE-3x5 box, securely screw it to wall or post and seal hole in box around wire with putty or
caulking. Note: Conduit may also be used when surface mounting wire, but should not enter through the top of the VE-3x5. When routing wiring
from above, a drip loop is required. WARNING: Do NOT use a typical "wet location box" as not all styles seal properly with the E-40 faceplate.
D. Mounting the Faceplate
After the Rough-In box or VE-3x5 is securely mounted, caulking between the box and rough opening is completed (if required), and wires are con-
nected, remove paper liner from face plate gasket. While firmly holding the LED light pipe in the faceplate, carefully slide the faceplate gasket over
the back of the light pipe and press gasket to the back of the faceplate. Push the 1-1/4" 6-32 screws through faceplate holes and small holes in gas-
ket, the faceplate gasket should retain the screws. Position Circuit board mounting plate over screws. Align screws with single gang box bosses and
tighten face plate until gasket is fully collapsed and the push button is protruding through the clearance hole in the face plate. Included 1/4" thick
gasket will provide an adequate seal for most siding surfaces; however for rough surfaces (ie: brick, stucco, etc.) additional caulking may be required.
1.8"
3.17"
4.92"
Conduit Knockout
Optional VE-3x5 Surface Mount
Box with Black Satin Powder Paint
Finish (not included) WARNING: Do
NOT use a wet location box.
E. Wiring the E-40
(Ring
connector
included)
** Earth
Ground
(optional)
Red
(Ring)
Green
(Tip)
IMPORTANT: Electronic devices are susceptible to lightning and power station electrical surges from both the AC
!
outlet and the telephone line. It is recommended that a surge protector be installed to protect against such surges.
* Note: The gel-filled (water-tight) butt connectors are designed for insulation displacement on 19-26 gauge wire with a maximum insulation of 0.082 inches. Do not strip wires prior
to terminating.
** Note: To increase surge protection, loosen the PCB mounting screw labeled
Earth Ground (grounding rod, water pipe, etc.) After fastening ring treminal to PCB mounting screw, bend terminal up to avoid interference with single gang box.
*** Note: Talk battery must be a minimum of 28V DC when using the speaker phone with a Viking K-1900-5 Dialer (DOD# 317) or K-1900-30 Multi-Number Dialer (DOD# 300).
**** Note: When installing a line powered phone on a low voltage and/or low loop current phone system extension, a Viking TBB-1B Talk Battery Booster may be required,
see DOD# 632.
P
r
o
g
r
a
m
m
P
r
o
g
r
a
m
m
A. Adjusting Speaker Volume
The speaker volume pot can be adjusted to increase or decrease the
speaker volume to the level desired.
B. Adjusting the Microphone Volume
In certain noisy locations (background traffic, machinery or wind), the
microphone volume may need to be decreased. A symptom of this is one-
way talk path, in which the distant party cannot be heard over the speak-
er. A microphone volume pot is provided for increasing or decreasing the
microphone volume. Note: If the microphone volume is set too high or
too low, one-way talk path may occur.
Optional
Optional Wing
Mounting Ears
Brackets
(2) Gel-Filled
2.00"
Wide
Butt Connectors
Min.
(included)
*2.25"
Deep
2.84"
Min.
Tall Min.
-OR-
Condensation
Drain Hole
(4) Optional Dry
Wall Screws
(not included)
"Old Work" Rough-In Box
(Allied Molded 9331 box
shown, not included)
* CAUTION: Excessive wire length and/or using a
rough-in box with inadequate depth can apply force
to the circuit board causing physical damage.
Rear View of the
E-40 Circuit Board
Mounting Plate
Viking C-200 or C-250 Single Entry
Phone Controller (not included)
VIKING
* Gel-Filled Butt
Connectors
(included) E-40
is not polarity
sensitive
ON
1
-or-
i
n
g
i
n
g
Red
Green
Circuit Board
Mounting Plate
(included)
** Important: Push LED light pipe into faceplate hole, then place faceplate
upside down on a clean flat surface and push down on back side of plate
until light pipe is fully seated and straight. WARNING: Inserting the light pipe
more than one time can cause a loose fit.
Viking C-2000B 1-4 Entry Phone
Controller (not included)
VIKING
MODEL C-200
©
VIKING
ELECTRONICS
HUDSON, WI 54016
ADVANCED DOOR/GATE AND
ENTRY PHONE CONTROLLER
SINGLE ENTRY PHONE
CONTROLLER
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7
8 9 1 0 11 12 13
J7-
1
2
3
LED1
LED2
LED3
C
C
2
3
EARTH
C.O. LINE
OUT TO
ENTRY
N.O. COM N.C.
GND
INPUT
PHONES
PHONE
AUX CONTACTS
(as shown above) and fasten a wire with ring terminal (included) from the mounting screw to
3.125"
4.875"
1/4" Thick Foam
Facplate
Faceplate Gasket
(included)
(included)
*** Optional Viking
K-1900-5 Dialer or
K-1900-30 Multi-
Number Dialer
MODEL C-2000B
©
(not included)
VIKING
ELECTRONICS
HUDSON, WI 54016
VIKING
©
Programmable
Tone Dialer
MODEL: K-1900-5
Quick Programming Guide
1. Call the phone connected to the dialer.
2. Answer phone. Enter
& security code.
(Factory set to 845464) Write your
security code below:
3. Enter your spped dial number & #00.
Note: For additional programming see
15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
K-1900-5 Technical Practice.
J10-
J8-
J9-
J11-
1
2
3
1
2
3
1
2
3
1
2
3
Viking Electronics, Inc.
Hudson, WI 54016
C
LED4
C
LED5
C
LED6
C
LED7
C
LINE IN
PHONE
To C.O. Line or
PABX/KSU station
To dedicated phone, unused trunk/
line input of a phone system, or
Viking C-1000B Doorbox Controller
Microphone
Volume
(see section B)
DIP
Switches
ON
ON
OFF
1 2 3 4
** LED
Light Pipe
(included)
(2) 6-32 x 1.25" Long
5/64" Hexdrive Flathead
Screws (included)
**** C.O. Line or Analog
PABX/KSU Station
(programmed for ringdown)
Viking DLE-200B
Two Way Ringdown
Circuit (not included)
VIKING
RINGDOWN
©
1
2
DLE-200B
RES
BUSY
Speaker
Volume
(see section A)
Rear View of the
E-40 Circuit Board
Mounting Plate
Note: Pots and DIP
switches are shown
in factory default set-
tings.

Advertisement

loading

This manual is also suitable for:

E-40-bk-ewpE-40-bnE-40-bn-ewpE-40-pbE-40-pb-ewpE-40-ss ... Show all