The Limiter - TC Electronic DBMAX-V 2.90 User Manual

V 2.90 digital broadcast maximizer broadcast series
Table of Contents

Advertisement

MAIN PAGE

The Limiter

Select LIM by pressing the BLOCK keys
Basic operation
- Press the PARAMETER keys to select parameter.
- Turn the ADJUST wheel to change values.
- Press the BAND keys to select between the five bands.
- Press the MENU keys to select User/Xpert/Xover.
Page 1
Threshold
Use the ADJUST wheel to change the Thresholds of the five
bands. The Thresholds refer to "Abs Peak max" in the Ref. Level
menu.
On/Off
Use these parameters to enable/disable the five Limiter bands.
Page 2
Press MENU keys to enter page2.
Attack
Use the ADJUST wheel to change the Attack time of the five
bands.
Release
Use the ADJUST wheel to change the Release time of the
five bands.
Limiter
Page 3 - Cross-over Menu
Press MENU keys to enter the Cross-over
frequency page (Xovr)
Cross-over point 1-4
Cross-over frequencies may be altered on the last page of the
Expander, Compressor and Limiter, but they are identical in all
three blocks.
Two different filter structures are available:
- SYM with soft slopes
- MID with higher order middle band focused filter slopes.
The MID setting is designed specifically for low intermodulation
between the bands, but if you want to emulate the TC Finalizer,
you should use a 3-band structure and a SYM slope setting.
Number of Bands
On the Cross-over page, outer bands may be turned off by
turning the cross-over points all the way up or down.
When a structure of less than 5 bands is used, the bands are also
removed from the graphic display.
Slope Types
Two different filter structures are available. SYM with soft slopes
and MID with higher order middle band focused filter slopes.
Cross-over frequency
Sets the Cross-over frequency for the selected Cross-over point.
Cross-over point
With Cross-over points 1-4 you set the Cross-over points
between the five bands in the dynamics section.
Note: The Cross-over points are common for the Compressor,
Limiter and Expander.
Limiter Bypass
Press the gray BLOCK on/off key to bypass the Expander
section.
35

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dbmax

Table of Contents