Page 3
<12005442 001> Page 2 of 78 Particulars: test item vs. test requirements Equipment mobility .............: Moveable Operating condition .............: Continuous Tested for IT power systems ........: Yes IT testing, phase-phase voltage (V) ......: IT, 230V for Norway Class of equipment ............: Class I Mass of equipment (kg) ..........: 4.76kg Protection against ingress of water ......: IPX0 Test case verdicts...
Page 4
<12005442 001> Page 3 of 78 Copy of marking plate(s): TRF No.: I950___E TRF originator: FIMKO...
Page 5
<12005442 001> Page 4 of 78 IEC 60950 Requirement Test Clause Result – Remark Verdict GENERAL Components 1.5.1 Comply with IEC 60950 or relevant component Components, which were standard found to affect safety aspects, comply with the requirements of this standard or within the safety aspects of the relevant IEC component standards (see appended table 1.5.1).
Page 6
<12005442 001> Page 5 of 78 IEC 60950 Requirement Test Clause Result – Remark Verdict C800 is certified as Y1 1.5.7.1 Bridging capacitors capacitor according to IEC 60 384-14/1993 1.5.7.2 Bridging resistors 1.5.7.3 Accessible parts The output connector is designed as limited current circuit (see sub-clause 2.4).
Page 7
Manufacturer’s name/Trademark ......: 1). Not shown/ COMPAL trademark 2). ASSOCIATED INDUSTRIES CHINA INC./ AG neovo trademark Type/model ............: GXX7X (X=0-9, A-Z or blank) Symbol of Class II ..........: Class I equipment Other symbols ............. : Other symbols do not give rise to misunderstanding.
Page 8
<12005442 001> Page 7 of 78 IEC 60950 Requirement Test Clause Result – Remark Verdict 1.7.8.4 Markings using figures ........: Not used. 1.7.9 Isolation of multiple power sources ..... : Equipment designed for only one connection to the mains. 1.7.10 IT power system For Norway compliance has...
Page 9
<12005442 001> Page 8 of 78 IEC 60950 Requirement Test Clause Result – Remark Verdict Test by inspection ..........: No access with test finger and test pin to any parts with only basic insulation to ELV or hazardous voltage. Test with test finger ..........
Page 10
<12005442 001> Page 9 of 78 IEC 60950 Requirement Test Clause Result – Remark Verdict 2.2.3 Voltages under fault conditions (V) ...... : Single fault did not cause excessive voltage in accessible SELV circuits. The limits of 71V peak and 120Vd.c.
Page 11
<12005442 001> Page 10 of 78 IEC 60950 Requirement Test Clause Result – Remark Verdict Measured voltage (V) ........... : <15k Measured capacitance (PF)........: <45µC 2.4.3 Connection of limited current circuits to other Complies. circuits Limited power sources Inherently limited output Impedance limited output Overcurrent protective device limited output...
Page 12
<12005442 001> Page 11 of 78 IEC 60950 Requirement Test Clause Result – Remark Verdict 2.6.4 Terminals See below. 2.6.4.1 Protective earthing and bonding terminals Appliance inlet used. Rated current (A), type and nominal thread Not permanently connected diameter (mm) ............: equipment.
Page 13
<12005442 001> Page 12 of 78 IEC 60950 Requirement Test Clause Result – Remark Verdict 2.7.1 Basic requirements The equipment relies on a 16A rated fuse or circuit breaker of the wall outlet protection of the building installation in regard to L to N short-circuits.
Page 14
<12005442 001> Page 13 of 78 IEC 60950 Requirement Test Clause Result – Remark Verdict 2.9.1 Properties of insulating materials Natural rubber, asbestos or hygroscopic materials are not used. 2.9.2 Humidity conditioning 40 ° C, 93% R.H. for 120 h (tropical conditions).
Page 15
<12005442 001> Page 14 of 78 IEC 60950 Requirement Test Clause Result – Remark Verdict 2.10.5.2 Thin sheet material The thin sheet materials of polyester tape used in transformer T801. Number of layers (pcs) ......... : 3 layers. Electric strength test 3000Vac applied on any combination of two layers.
Page 16
<12005442 001> Page 15 of 78 IEC 60950 Requirement Test Clause Result – Remark Verdict 3.1.1 Current rating and overcurrent protection All internal wires are UL recognized wiring which is PVC insulated, rated VW-1, 300V, min. 80° C. Internal wiring gauge is suitable for current intended to be carried.
Page 17
<12005442 001> Page 16 of 78 IEC 60950 Requirement Test Clause Result – Remark Verdict 3.2.4 Appliance inlets The appliance inlet complies with IEC/EN 60320. The power cord can be inserted without difficulties and does not support the unit. 3.2.5 Power supply cords Type..............
<12005442 001> Page 17 of 78 IEC 60950 Requirement Test Clause Result – Remark Verdict 3.4.1 General requirement Disconnect device provided. 3.4.2 Disconnect devices Appliance inlet. 3.4.3 Permanently connected equipment Not permanently connected equipment. 3.4.4 Parts which remain energized When the power cord is removed from the inlet (or wall socket) no remaining parts...
Page 19
<12005442 001> Page 18 of 78 IEC 60950 Requirement Test Clause Result – Remark Verdict Mechanical strength 4.2.1 General See below. After the tests, the equipment complies with the requirements of sub-clauses 2.1.1, 2.6.1, 2.10 and 4.4.1. 4.2.2 Steady force test, 10 N 10N applied to all components other than enclosure.
Page 20
<12005442 001> Page 19 of 78 IEC 60950 Requirement Test Clause Result – Remark Verdict 4.3.2 No handles or controls provided. 4.3.3 Adjustable controls No controls provided. 4.3.4 Securing of parts Mechanical fixings in such a way designed that they will withstand mechanical stress occurring in normal use.
Page 21
<12005442 001> Page 20 of 78 IEC 60950 Requirement Test Clause Result – Remark Verdict Thermal requirements 4.5.1 Temperature rises See appended table. 4.5.2 Resistance to abnormal heat Only Phenolic materials used where parts at hazardous voltage are directly mounted on.
Page 22
<12005442 001> Page 21 of 78 IEC 60950 Requirement Test Clause Result – Remark Verdict 4.7.3.2 Materials for fire enclosures Plastic enclosure of flammability class V-0 or better. For details see table 1.5.1 and metal enclosure is used for the power supply and main board.
Page 23
<12005442 001> Page 22 of 78 IEC 60950 Requirement Test Clause Result – Remark Verdict Test voltage (V) ........... : Measured current (mA) ........: Max. allowed current (mA) ........: No TNV. 5.1.8.2 Summation of touch currents from telecommunication networks ........
Page 24
<12005442 001> Page 23 of 78 IEC 60950 Requirement Test Clause Result – Remark Verdict CONNECTION TO TELECOMMUNICATION NETWORKS Protection of telecommunication network service personnel, and users of other equipment connected to the network, from hazards in the equipment 6.1.1 Protection from hazardous voltages 6.1.2...
Page 25
<12005442 001> Page 24 of 78 IEC 60950 Requirement Test Clause Result – Remark Verdict Sample 2 burning time (s)........: Sample 3 burning time (s)........: Flammability test for fire enclosures of movable equipment having a total mass not exceeding 18 kg, and for material and components located inside fire enclosures (see 4.7.3.2 and 4.7.3.4) A.2.1...
Page 26
<12005442 001> Page 25 of 78 IEC 60950 Requirement Test Clause Result – Remark Verdict A.4.1 Samples Wall thickness (mm) ..........: A.4.2 Test circuit A.4.3 Mounting of samples..........: A.4.4 Test procedure A.4.5 Compliance criteria Sample 1 ignition time (s) ........: Sample 2 ignition time (s) ........
Page 27
<12005442 001> Page 26 of 78 IEC 60950 Requirement Test Clause Result – Remark Verdict A.7.8 Permitted retest, HF-1 or HF-2 A.7.9 Permitted retest, HBF Flammability test for classifying materials HB A.8.1 Samples Sample thickness (mm) ........: A.8.2 Conditioning of samples;...
Page 28
<12005442 001> Page 27 of 78 IEC 60950 Requirement Test Clause Result – Remark Verdict Test duration (days) ..........: Electric strength test: test voltage (V) ....: Running overload test for DC motors in secondary circuits Locked-rotor overload test for DC motors in secondary circuits B.7.1 Test procedure B.7.2...
Page 29
<12005442 001> Page 28 of 78 IEC 60950 Requirement Test Clause Result – Remark Verdict ANNEX G, ALTERNATIVE METHOD FOR DETERMINING MINIMUM CLEARANCES Summary of the procedure for determining minimum clearances Determination of mains transient voltage (V)..: Determination of telecommunication network transient voltage (V) ..........
Page 30
<12005442 001> Page 29 of 78 IEC 60950 Requirement Test Clause Result – Remark Verdict Adding machines and cash registers Erasers Pencil sharpeners Duplicators and copy machines Motor-operated files Other business equipment ANNEX M, CRITERIA FOR TELEPHONE RINGING SIGNALS (see 2.3.1) Introduction Method A Method B...
Page 31
<12005442 001> Page 30 of 78 1.5.1 TABLE: list of critical components object/part No. manufacturer/ type/model technical data standard mark(s) of trademark conformity LCD Monitor Switch power Compal VP-719 I/P: 90-264Vac, supply 47.5-63Hz, 1.2- 0.6A. O/P: 5Vdc, 1.5A max; 13Vdc, 2.2A max.
Page 32
<12005442 001> Page 31 of 78 Switching Power Supply 10A, 250Vac IEC60320 VDE, UL, CSA, AC Inlet (P801) Hua-Jie SA-4S NEMKO Littelfuse AC Fuse (F801) T3.15A, 250V IEC60127-2 VDE, UL, CSA Wickmann 181, 195 T3.15A, 250V IEC60127-2 VDE, UL, CSA Class 130 Line filter (L801, Li Shin...
Page 33
<12005442 001> Page 32 of 78 applicable parts accepted by Main Li Shin DG100016400 Class B in IEC 60950 TUV Rheinland Transformer and according to (T801) IEC 60085 applicable parts accepted by YUVA DG100016400 Class B in IEC 60950 TUV Rheinland and according to IEC 60085 applicable parts...
Page 34
<12005442 001> Page 33 of 78 Discharge resistor : 1020k: (R801=R802=510k:) 2.2.2 TABLE: Hazardous voltage measurement Transformer Location max. Voltage Voltage Limitation Component V peak V d.c. T801 pin 7-9 33.0 pin 8-9 25.6 pin 12-9 51.20 25.9 D841 2.2.2 TABLE: SEL voltage measurement Location Voltage measured (V)
Page 35
<12005442 001> Page 34 of 78 J940 pin 1 – GND 6.24 3.12 53.41 37.38 with C922 shorted J940 pin 1 – GND -- with U920 pin 1-8 shorted, inverter damaged, no hazards T901 pin 5 – 4 (GND) -- with normal condition, unit shut down, no hazards T901 pin 5 –...
Page 37
<12005442 001> Page 36 of 78 under C803 on SPS under C804 on SPS under C803A on SPS near F801 on SPS near RT801 on SPS Primary traces o secondary <250 <420 trace C818 to W31 on SPS J801 to D948 on SPS F801 to D947 on SPS P801 to D947 on SPS under C800 on SPS...
Page 38
<12005442 001> Page 37 of 78 t2 (qC) ..............: -- 'T (K) rise dT of part/at: allowed dT (K) Test voltage U4 body (main board) 44.5 43.5 PCB near U4 (main board) 39.8 39.2 U5 body (main board) 36.1 35.4 C805 top (power supply) 32.3...
Page 39
<12005442 001> Page 38 of 78 Comments: The temperatures were measured under worst case normal mode defined in 1.2.2.1 and as described in 1.6.1 at voltages as described in 1.6.5. With a specified ambient temperature of 40° C, the max. temperature rise is calculated as follows: Winding components: o 'Tmax = 95K - 10K - (40-25)K = 70K - class B...
Page 40
<12005442 001> Page 39 of 78 N o terminal A Condition Lo terminal A Limit (mA) comments (mA) (mA) Unit ON 0.82 0.75 Output connector. Unit OFF 0.82 0.75 Output connector. Fuse out 1.17 0.45 Output connector. Input voltage : 254V Input frequency: 60Hz Overall capacity: C803=C804=C803A=4700pF, C800=2200pF TABLE: electric strength tests and impulse tests...
Page 42
<12005442 001> Page 41 of 78 0.06 Unit shut down, no T801 pin 7 - 9, <1 sec F801 components damaged, no 10, 11 hazards 0.3 Unit shut down, no D841 pin 2 – <1 sec F801 components damaged, no 1, 3 hazards T801 pin...
Page 43
<12005442 001> Page 42 of 78 supplementary information: Total afterflame time (s) for any condition set t for five (5) specimens: A.7.4, TABLE: flammability test for classifying foam materials HF-1, HF-2 or HBF A.7.5, A.7.6 and A.7.7 sample flame time (s) glow time (s) flaming/glowing distance comment...
Page 44
<12005442 001> Page 43 of 78 supplementary information: A.7.9 TABLE: flammability test for classifying foam materials HBF sample flame time (s) glow time (s) flaming/glowing distance comment from the end (mm) (for A.7.7 burning rate mm/min) supplementary information: A.8.5 TABLE: flammable test for classifying materials HB sample flaming/glowing rate flaming/glowing distance from reference mark...
Page 45
<12005442 001> Page 44 of 78 A.9.6 TABLE: flammability test for classifying materials 5V sample test bars test plaques No. / ref. flaming + glowing time burning distance flaming + glowing time burning distance (mm) (mm) 10/B supplementary information: A.9.7 TABLE: flammability test for classifying materials 5V sample test bars...
Page 46
<12005442 001> Page 45 of 78 Required clearance for reinforced insulation (from table 2H and 2J) 4.0+0.4mm Effective voltage rms 253 Vrms Required creepage for reinforced insulation (from table 2L with linear interpolation) 5.2mm Measured min. creepages Location inside (mm) outside (mm) Primary-secondary Primary-core...
Page 47
<12005442 001> Page 46 of 78 National Differences Requirement Test Clause Result – Remark Verdict APPENDIX CENELEC common modifications (Group differences), Special national conditions and A-deviations according to CB Bulletin No. 103A, July 2002 EN 60950: 2000 (BS EN 60950:2000, NEK EN 60950, SS EN 60950 6 (IEC Publication 60950: 1999) EXPLANATION FOR ABBREVIATIONS C=CENELEC common modification, S=Special national condition, A=A-deviations...
Page 48
<12005442 001> Page 47 of 78 National Differences Requirement Test Clause Result – Remark Verdict “For tilslutning af de øvrige ledere, se medfølgende installationsvejledning”. 1.7.2 S (SE) In Sweden, if the separation between the To be provided when mains and SELV terminal relies upon submitted for natinal approval.
Page 49
<12005442 001> Page 48 of 78 National Differences Requirement Test Clause Result – Remark Verdict 1.7.15 A (CH) Switzerland (Ordinance on environmentally No batteries provided. hazardous substances SR 814.013) Annex 4. 10 of SR 814.013 applies for batteries. 2.2.4 S (NO) In Norway, requirements according to this Equipment not intended to be annex, sub-clauses 1.7.2 and 6.1.2.1 apply.
Page 50
<12005442 001> Page 49 of 78 National Differences Requirement Test Clause Result – Remark Verdict 2.10.3.1 S (NO) In Norway, due to the IT power distribution Considered. system used (see annex V, figure V.7), the A.C. MAINS SUPPLY voltage is considered to be equal to the line-to-line voltage, and will remain at 230 V in case of a single earth fault.
Page 51
<12005442 001> Page 50 of 78 National Differences Requirement Test Clause Result – Remark Verdict D1 or EN 60309-2. 3.2.1 S (ES) In Spain, supply cords of single-phase To be evalauted when equipment having a rated current not exceeding submitted for national 10 A shall be provided with a plug according to approval.
Page 52
<12005442 001> Page 51 of 78 National Differences Requirement Test Clause Result – Remark Verdict “60227 IEC 53” by “H05 VV-F or H05 VVH2-F2” In table 3B, replace the first four lines by the following: Up to and including 6 0,75 Over 6 up to and including (0,75)
Page 53
<12005442 001> Page 52 of 78 National Differences Requirement Test Clause Result – Remark Verdict 4.3.13 C Replace the second compliance paragraph by: Replaced. For equipment using LEDs or lasers, See IEC 60950 test report. compliance is checked according to EN 60825- NOTE 1 - if equipment falling within the scope of EN 60950 is inherently a class 1 laser product, i.e., it contains no embedded laser or LD of a...
Page 54
<12005442 001> Page 53 of 78 National Differences Requirement Test Clause Result – Remark Verdict Annex G.2 (NO) In Norway, due to the IT power distribution Annex G not considered. system used (see annex V, figure V.7), the A.C. MAINS SUPPLY voltage is considered to be equal to the line-to-line voltage, and will remain at 230 V in case of a single earth fault.
Page 55
<12005442 001> Page 54 of 78 National Differences Requirement Test Clause Result – Remark Verdict the electron acceleration voltage must not exceed the maximum value stipulated by the manufacturer or importer. Furthermore, a licence in accordance with clause 1 is also not required by persons who operate X-ray emission sources on the X-rays are generated only by intrinsically safe CRTs complying with Enclosure III, No.
Page 56
<12005442 001> Page 55 of 78 National Differences Requirement Test Clause Result – Remark Verdict HD 214 S2:1980 IEC 60112:1979 HD 21 Series IEC 60227 (mod) Series HD 22 Series IEC 60245 (mod) Series EN 60309 Series IEC 60309 Series EN 60320 Series IEC 60320 (mod) Series HD 384.3 S2:1995...
Page 57
<12005442 001> Page 56 of 78 National Differences Requirement Test Clause Result – Remark Verdict APPENDIX Canadian National Differences according to CB Bulletin No. 103A, July 2002 (CAN/CSA C22.2 No. 60950/UL60950, Third edition) (IEC Publication 60950:1999) EXPLANATION FOR ABBREVIATIONS P=Pass, F=Fail, N=Not applicable.
Page 58
<12005442 001> Page 57 of 78 National Differences Requirement Test Clause Result – Remark Verdict 2.7.1 Suitable CEC/NEC branch circuit protection is No such components required for all standard supply outlets, provided. receptacles and medium-base or smaller lampholders if the supply branch circuit protection is not suitable.
Page 59
<12005442 001> Page 58 of 78 National Differences Requirement Test Clause Result – Remark Verdict 3.4.10 For computer room applications, equipment with No battery system battery systems capable of supplying 750 VA for incorporated. five minutes are required to have a battery disconnect means that may be connected to the computer room remote power-off circuit.
Page 60
<12005442 001> Page 59 of 78 National Differences Requirement Test Clause Result – Remark Verdict Where necessary, it will also be subject to the applicable tests of the equipment standard, and to the applicable tests of the Canadian and/or U.S.
Page 61
<12005442 001> Page 60 of 78 National Differences Requirement Test Clause Result – Remark Verdict Continuous ringing signals up to 16 mA only are permitted if the equipment is subject to special installation and performance restrictions. Annex NAB Equipment connected to centralized d.c. power systems is required to comply with special earthing, wiring, marking and insulation requirements in accordance with Annex NAB and...
Page 62
<12005442 001> Page 61 of 78 National Differences Requirement Test Clause Result – Remark Verdict APPENDIX Japanese National Differences according to CB Bulletin No. 103A, July 2002 (J60950(H14)) (IEC Publication 60950:1999) EXPLANATION FOR ABBREVIATIONS P=Pass, F=Fail, N=Not applicable. Placed in the column to the right. Addition: Added.
Page 63
<12005442 001> Page 62 of 78 National Differences Requirement Test Clause Result – Remark Verdict NOTE 2 - Similarly, other MATERIALS, including rigid (engineering structural) foam of CLASSES 5V or V-0 are regarded as better than those of CLASS V-1, V-1 better than V-2, and V-2 better than HB.
Page 64
<12005442 001> Page 63 of 78 National Differences Requirement Test Clause Result – Remark Verdict 2.6.4.1 Replacement: Replaced. Replace 2nd sentence in 1st paragraph. For CLASS I EQUIPMENT with a DETACHABLE POWER SUPPLY CORD, the earthing terminal in the appliance inlet is regarded as the main protective earthing terminal.
Page 65
<12005442 001> Page 64 of 78 National Differences Requirement Test Clause Result – Remark Verdict Add 7) to Table 4A, Part 2 as follows. 7) This value shall apply only to wiring or cords complying with relevant IEC standards. Others shall comply with Japanese requirements (refer to Japanese differences for the current IEC 60335-1 (3rd Edition) in CB Bulletin 101B).
Page 66
<12005442 001> Page 65 of 78 National Differences Requirement Test Clause Result – Remark Verdict If peak values of TOUCH-CURRENT are measured, the maximum values obtained by multiplying the r.m.s. values by 1,414. 5.3.8.2 Replacement: Replaced. Replace 3rd item as follows. BASIC INSULATION between the PRIMARY CIRCUIT and accessible conductive parts of CLASS I or 0I EQUIPMENT;...
Page 67
<12005442 001> Page 66 of 78 National Differences Requirement Test Clause Result – Remark Verdict U.2.2 Replacement: Flexibility and adherence Test 8 of IEC 60851-3:1996, 5.1.1, using the mandrel diameters of table U.1. The test sample is then examined in accordance with IEC 60851- 3:1996, 5.1.1.4, followed by the test of 5.2.2 of this standard except applying the test voltage between the wire and the mandrel.
Page 68
<12005442 001> Page 67 of 78 National Differences Requirement Test Clause Result – Remark Verdict APPENDIX Korean National Differences according to CB Bulletin, No. 103A, July 2002 (K60950) (IEC Publication 60950:1999) EXPLANATION FOR ABBREVIATIONS P=Pass, F=Fail, N=Not applicable. Placed in the column to the right. 1.5.101 Addition: No power cord set provided.
Page 69
<12005442 001> Page 68 of 78 National Differences Requirement Test Clause Result – Remark Verdict APPENDIX US National Differences according to CB Bulletin No. 103A, July 2002 (UL 60950) (IEC Publication 60950:1999) EXPLANATION FOR ABBREVIATIONS P=Pass, F=Fail, N=Not applicable. Placed in the column to the right. Special National Conditions 1.1.1 All equipment is to be designed to allow...
Page 70
<12005442 001> Page 69 of 78 National Differences Requirement Test Clause Result – Remark Verdict Wiring methods (terminals, leads, etc.) used for Approved appliance inlet the connection of the equipment to the mains provided. shall be in accordance with the NEC. 3.2.1 Power supply cords are required to have No power cord provided.
Page 71
<12005442 001> Page 70 of 78 National Differences Requirement Test Clause Result – Remark Verdict 4.3.13 Equipment with lasers is required to meet Code No lasers incorporated. For of Federal Regulations 21 CFR 1040 and indicator LED see IEC 60950 Canadian Radiation Emitting Devices Act, REDR test report.
Page 72
<12005442 001> Page 71 of 78 National Differences Requirement Test Clause Result – Remark Verdict 2.3.1 For TNV-2 and TNV-3 circuits with other than Equipment not considered for ringing signals and with voltages exceeding TNV connection. 42.4 Vp or 60 Vd.c., the maximum acceptable current through a 2000 ohm resistor (or greater) connected across the voltage source with other loads disconnected is 7.1 mA peak or 30 mAd.c.
Page 73
<12005442 001> Page 72 of 78 National Differences Requirement Test Clause Result – Remark Verdict APPENDIX Australian National Differences according to AS/NZS 60950:2000 (IEC Publication 60950:1999) EXPLANATION FOR ABBREVIATIONS P=Pass, F=Fail, N=Not applicable. Placed in the column to the right. Between the definitions for "frequency, rated"...
Page 74
<12005442 001> Page 73 of 78 National Differences Requirement Test Clause Result – Remark Verdict Over 6 up to (0,75) 1,00 16 [1,3] and including Over 10 up to (1,0) 1,5 14 [2] and including This nominal cross-sectional area is only allowed for Class II appliances if the length of the power supply cord, measured between the point where the cord, or cord guard, enters the...
Page 75
<12005442 001> Page 74 of 78 National Differences Requirement Test Clause Result – Remark Verdict 6.2.2 Replace the first paragraph with the following Replaced. variation: In Australia (this variation does not apply in New Zealand), compliance with 6.2.2 is checked by the tests of both 6.2.2.1 and 6.2.2.2) 6.2.2.1 Replace Clause 6.2.2.1 with the following...
Page 76
<12005442 001> Page 75 of 78 National Differences Requirement Test Clause Result – Remark Verdict Electrotechnical Vocabulary – Part 151: Electrical and magnetic devices (identical to IEC 60050- 151) AS/NZS 60065:2000, Safety requirements for Mains operated electronic and related apparatus for household and similar general use.
Page 77
<12005442 001> Page 76 of 78 National Differences Requirement Test Clause Result – Remark Verdict Annex Q Replace the marginally barred informative Replaced. references with the following: AS 2005.21.1–1990, Low voltage fuses – Fuses with enclosed fuse–links Part 21.1: Supplementary requirements for fuses for use by authorized persons (Fuses mainly for industrial application) –...
Page 78
<12005442 001> Page 77 of 78 National Differences Requirement Test Clause Result – Remark Verdict APPENDIX Singaporean National Differences (SS 337:2001) (IEC Publication 60950:1999) EXPLANATION FOR ABBREVIATIONS P=Pass, F=Fail, N=Not applicable. Placed in the column to the right. General IT Power Systems are not allowed in the Connection to IT power Republic of Singapore and all clauses related to...
Page 79
<12005442 001> Page 78 of 78 National Differences Requirement Test Clause Result – Remark Verdict 1.2.8.6 After NOTE 2, insert the following: Inserted. NOTE 3 – This definition for SELV CIRCUIT differs from the term ’SELV system’ as given in SS CP 5.