Connection to the gas supply, or conversion from one type of gas to
another, should only be undertaken by an approved and registered gas
installer in strict accordance with local and national safety and building
regulations (e.g. Gas Safe registered in the U.K.).

Jet table

When converting to a different type of gas, the main burner jet and the small
burner jets have to be changed.
Natural gas / liquid
gas
Small burner
Medium burner
Large burner
Wok
Liquid gas
Small burner
Medium burner
Large burner
Wok
The jet markings refer to 1/100 mm of the jet diameter.

Conversion to another type of gas

Main burner jet Ø
0.69
0.95
1.10
1.35
0.50
0.65
0.78
0.98
Small burner jet Ø
0.39
0.42
0.54
0.80
0.27
0.32
0.40
0.54