Electrical Connection - Miele KM 460 Operating Instructions Manual

Ceramic
Hide thumbs Also See for KM 460:
Table of Contents

Advertisement

All electrical work should be carried
out by a suitably qualified and
competent person in strict
accordance with national and local
safety regulations.
Installation, repairs and other work
by unqualified persons could be
dangerous. The manufacturer
cannot be held liable for
unauthorised work.
Ensure power is not supplied to the
appliance until after installation or
repair work has been carried out
The appliance must only be
operated when built-in. This is to
ensure that all electrical parts are
shielded. Live parts must not be
exposed.
Do not connect the appliance to the
mains electricity supply by an
extension lead. These do not
guarantee the required safety of the
appliance.
The voltage and connected load are
given on the data plate. Ensure that
these match the household mains
supply.

Electrical connection

Connection should be made via a
suitable isolator which complies with
national and local safety regulations,
and the On/Off switch should be easily
accessible after the appliance has
been built in.
If the switch is not accessible after
installation (depending on country) an
additional means of disconnection must
be provided for all poles.
For extra safety it is advisable to install
a residual current device (RCD), with a
trip current of 30 mA.
When switched off there must be an
all-pole contact gap of at least 3 mm in
the isolator switch (including switch,
fuses and relays).
Important U.K.
The appliance is supplied for
connection to a 230-240 V, 50 Hz
supply with a 3-core cable.
The wires in the mains lead are
coloured in accordance with the
following code:
Green/yellow = earth
Blue
= neutral
Brown
= live
31

Advertisement

Table of Contents
loading

This manual is also suitable for:

Km 461

Table of Contents