Connecting Loads; Grounding The Generator - Titan 6500 Owner's Manual

Industrial generator
Hide thumbs Also See for 6500:
Table of Contents

Advertisement

P.O. Box 791
Travelers Rest, S.C. 29690
864-834-7212
Toll Free 1-888-828-8126
Replacement Parts 1-800-845-4141
MODEL TG 6500
GAS POWERED
ELECTRIC GENERATOR
Model
Voltage
Frequency
Continuous Watts
Surge Watts
DESCRIPTION
TITAN MODEL TG6500 is a gas engine driven, revolv-
ing field, alternating current (AC) generator designed to
supply electrical power for compatible electrical tools,
motors, appliances, and lighting (see wattage reference
guide on page 8 ).
The Model TG 6500 operates at 120 volt and/or 240 volt,
single phase, 60 Hz and will operate devices that require
up to 6000watts continuous, 6800 surge watts.
Figure #1 - Grounding Lug Block
TG 6500
120/240
60Hz
6000
6800
3

CONNECTING LOADS

Add up the Watts of all devices you connect to the Titan
Generator at one time. Do not exceed 6000 Watts on
Titan Generator Model TG 6500RC (see wattage refer-
ence guide).
The rated Watts of most electrical devices can be found
on its nameplate. The rated Watts of lights can be taken
from the light bulbs. In cases where only Volts and Amps
are shown on the nameplate, simply multiply Volts by
the Amps to get Watts (Volts X Amps = Watts).
Some electric motors require about three times the
rated Watts of power for start-up. This surge of power is
required for only a few seconds. Be sure to allow for this
high starting wattage when selecting electrical devices
to connect to the generator.
First, figure the watts needed to start the largest motor.
Add to that figure the running watts of all other con-
nected loads.
Please see the Wattage Reference Guide.
It provides an estimated approximation of running watts,
to help determine which devices to select to connect to
the generator.
CAUTION! Do not tamper with engine governed speed.
The TITAN Generator supplies correct rated frequency
and voltage when running at the proper governed speed.
Incorrect frequency and/or voltage could damage con-
nected electrical devices.

GROUNDING THE GENERATOR

It is required by The National Electrical Code to have the
frame and all external conductive parts of the generator
connected to an earth ground. Proper grounding also
satisfies most local electrical codes.
Connect a No. 12 AWG standard copper wire to the
Grounding Lug Block (See Figure 1). The grounding
lug can be found on the front of the contorl panel. Con-
nect the other end of the wire to an earth driven copper
or brass grounding rod (electrode).
CAUTION! Do not connect ground to a preexisting
ground rod, water pipe, or building frame.
Consult with a licensed electrician in your area because
local codes vary. Properly grounding the generator helps
prevent electrical shock if a ground fault condition exists
in the generator or in connected electrical devices. This
will also help to dissipate static electricity resulting from
ungrounded devices.