/ZIO PLUS LCD WALL MODULES
SET VIEW MORE - allows the contractor to give additional
parameter access (view only or adjustable) to the tenant.
PARAMETERS - allows the contractor to monitor and/or
adjust parameters in the programmable controller.
Fig. 8. Sample Contractor parameter display showing
user-created discharge air parameter value.
Fig. 9. Sample Contractor parameter display showing
sensor setpoint value (CO
NOTE: Any configured parameter may be displayed.
ComfortPoint™ is a trademark of Honeywell International Inc.
L
M
® is a trademark of the LonMark Association.
ON
ARK
BACnet® is a registered trademark of BACnet International.
Spyder® is a registered trademark of Honeywell International Inc.
Sylk® is a registered trademark of Honeywell International Inc.
Zio® is a registered trademark of Honeywell International Inc.
Automation and Control Solutions
Honeywell International Inc.
1985 Douglas Drive North
Golden Valley, MN 55422
customer.honeywell.com
M27358
M27359
sensor from controller).
2
® U.S. Registered Trademark
© 2011 Honeywell International Inc.
63-1322—02
Printed in United States
TYPICAL SPECIFICATION
1. The wall module shall have an LCD display.
2. The wall module shall have a customizable home
screen:
a. Shall have the option to show up to 3 parameter
values on a single display.
b. Shall have the option to show occupied status.
c. Shall have the option to show system status.
d. Shall have the option to show fan status.
e. Shall have the option to show up to three of the fol-
lowing parameters:
• room temperature, setpoint, outside
temperature, room humidity, outside humidity,
time of day.
f.
Shall have the option to show on the home screen
any single parameter in the controller, with a user
defined 8 letter name.
3. The wall module shall offer access to all parameters
necessary to balance a VAV system.
4. The wall module shall offer the ability to restrict access
to parameter information with keypad enabled lock out
and with optional 4 digit password protection (password
on TR71 and TR75 only).
5. The wall module shall retain user configuration including
setpoints after power outage.
6. The wall module shall use a two wire polarity insensitive
connection for all communication and power needs.
7. The wall module shall offer the ability to access and
adjust virtually all controller parameters.
8. The wall module shall offer the ability for the tenant to
adjust override time period within the limits set by the
contractor.
9. The wall module shall offer a communication jack for
remote access to the network.
10. The wall module shall offer a ± 5% on board humidity
sensor (TR70-H, TR71-H, and TR75-H only).
11. The wall module shall be configured through the Honey-
well WEBs-AX Workbench tool.
12. The wall module shall communicate with other devices
using the Sylk bus protocol.
13. The wall module shall be compatible with LON and
BACnet controllers.
14. The wall module shall offer the ability to view/edit the
controller's schedule (TR75 only).
15. The wall module shall have the ability to display enu-
merated values as text.
16. The wall module shall have the ability to use the value of
a parameter as the upper or lower limit of another
parameter (TR75 only).