ACV Delta G20 Installation & Operating Manual

ACV Delta G20 Installation & Operating Manual

Combination boiler with atmospheric burner

Advertisement

Quick Links

INSTALLATION, OPERATING
AND SERVICING INSTRUCTIONS
DELTA Classic
Combination boiler
with atmospheric burner
05/11/2002
ACV reserves the right to modality the technical specifications and components of its products without prior notice.
664Y0100

Advertisement

loading

Summary of Contents for ACV Delta G20

  • Page 1 INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS DELTA Classic Combination boiler with atmospheric burner 05/11/2002 ACV reserves the right to modality the technical specifications and components of its products without prior notice. 664Y0100...
  • Page 2 The product must be installed and serviced by qualified engineers, in compliance with the prevailing standards. ACV accepts no liability for any damage resulting from incorrect installation or from the use of components or fittings not specified by ACV.
  • Page 3: Installation

    3. Circulator 4. Non-return valve 5. System filling valve 6. Expansion tank 7. Room thermostat 8. ACV 13 controller (see controller kit page 5) 9. Central heating isolating valve 10. Drain valve Fig. 1: Boiler room ventilation and chimney connection...
  • Page 4: Domestic Hot Water Connection

    If the water mains pressure is greater than 6 bar, a pressure reducer calibrated to 4.5 bar must be fitted. 2.2.3.2 Safety unit The tank safety unit must be ACV approved and calibrated to 7 bar. The valve discharge must be connected to the sewer drain. 2.2.3.3 Hot water expansion tank Installing a hot water expansion tank avoids any risk of pressure surges due to water-hammer.
  • Page 5: Electrical Connection

    INSTALLATION 2.2.4 CONTROLLER KITS KIT 1: ACV 13.00 / Basic Basic kit for regulating flow temperature according to weather conditions. It comprises: temperature regulator with analogue timer, water temperature detector (-30/130° C), outside temperature detector (-30/50° C), 230V - 3 spindle servomotor SQY 31 Fig.
  • Page 6 FILLING THE HEATING AND HOT RECOMMENDATION WATER CIRCUITS ACV advises that boilers should be serviced at least once a year. The burner must be serviced and tested by a competent engineer. 1. Fill the domestic hot water circuit and bring it up to pressure.
  • Page 7: Servicing The Burner

    6. After emptying, return the valves to their initial positions. For the tank to be emptied, valve (C) must be situated at ground level. SPARE PARTS Refer to the specific document available from ACV or your distributor. Fig. 12b: Emptying the hot water circuit...