11. Installation, relocation and inspection
Also consider operation sound
• Do not put an object around the air outlet of the outdoor unit. It may cause lowering of capacity or increase operating sound.
• If abnormal sound is heard during operation, consult your dealer.
Relocation
• When the air conditioner is to be removed or reinstalled because of rebuilding, moving, etc., special techniques and work are required.
Warning:
Repair or relocation should not be done by the customer.
If this is done incorrectly, it may cause a fire, electric shock, injury by dropping of the unit, water leakage, etc. Consult your dealer.
Disposal
• To dispose of this product, consult your dealer.

12. Specifications

Model
Function
Power supply
kW
Capacity
BTU/h
Input
kW
Indoor unit
Airflow (Lo-Mid-Hi)
CMM
Ext. static pressure
Pa
Noise level (Lo-Mid-Hi)
dB
Weight
kg
Outdoor unit
Noise level
dB
Refrigerant R410A
kg
Weight
kg
Notes: 1. Rating conditions (cooling) Indoor : 27
2. Rating conditions (heating) Indoor : 20
3. Specifications subject to change without notice.
4. The external static pressure is set to 15 Pa at factory shipment.
Guaranteed operating range
Upper limit
32°C DB, 23°C WB
Cooling
Lower limit
21°C DB, 15°C WB
Upper limit
Heating
Lower limit
Units should be installed by licensed electric contractor accordingly to local code requirement.
If you have any question, consult your dealer.
SEZ-KD25VA
SEZ-KD35VA
Cooling
Heating
Cooling
2.5
3.0
3.5
8,500
10,200
11,900
0.04
0.04
0.05
SEZ-KD25VA
SEZ-KD35VA
5.5-7-9
7-9-11
5/15/35/50
5/15/35/50
23-26-30
23-28-33
18
SUZ-KA25VA
SUZ-KA35VA
46
0.90
1.05
33
°
°
C DB, 19
C WB
°
C DB
Outdoor
Indoor
KD25, KD35 KD50, KD60, KD71
46°C DB, – 43°C DB, –
-10°C DB, –
27°C DB, –
24°C DB, 18°C WB
20°C DB, –
-10°C DB, -11°C WB
SEZ-KD50VA
Heating
Cooling
Heating
~/N, 230V, 50Hz
4.0
5.0
5.9
13,600
17,100
20,100
0.05
0.07
0.07
SEZ-KD50VA
10-12.5-15
5/15/35/50
30-34-37
21
23
SUZ-KA50VA
48
55
1.6
35
53
°
Outdoor : 35
C DB
°
°
Outdoor : 7
C DB, 6
C WB
SEZ-KD60VA
SEZ-KD71VA
Cooling
Heating
Cooling
5.5
6.9
7.1
18,800
23,500
24,200
0.07
0.07
0.10
SEZ-KD60VA
SEZ-KD71VA
12-15-18
12-16-20
5/15/35/50
5/15/35/50
30-34-38
30-35-40
27
27
SUZ-KA60VA
SUZ-KA71VA
55
55
1.8
2.0
53
58
Heating
8.1
27,600
0.10
17