The AD-8922A functions in two ways as follows, depending on the weighing instrument used:
A remote controller that displays the weighing data and remotely controls the weighing instrument.
A remote display that displays the weighing data.
Available key operations depend on the weighing instrument used, as shown below. Set the command set
C5et
"
" of the function setting, appropriate to the weighing instrument.
Weighing
instrument
AD-4212C
GX, GX-K, GP,
GH, ET-W, FZ-i
GR
GF, GF-K,
EK-H,
AD-4212A/B, HR,
HR-i, FX-i
EK-i, EW-i
EK-G, EW-G, FC-i,
FC-Si, FG, FG-L,
FG-M, FP, FS, FS-KL,
HV-G, HV-WP, HW-G,
HW-WP
Note: "⎯" in the table indicates that the key operation is not available.
*1: Switching the standby or weighing mode is available for the AD-4212C.
*2: Not applicable to the counting mode and the percent mode. Switching the minimum display
is not available for the ET-W.
*3: Available when the AD-8922A is in key mode ("
*4: Not available for the ET-W and AD-4212
*5: AD-8922A function settings
1-3Compliance
1-3-1 Compliance with FCC Rules
Please note that this equipment generates, uses and can radiate radio frequency energy. This
equipment has been tested and has been found to comply with the limits of a Class A computing
device pursuant to Subpart J of Part 15 of FCC rules.
reasonable protection against interference when equipment is operated in a commercial
environment. If this unit is operated in a residential area, it may cause some interference and under
these circumstances the user would be required to take, at his own expense, whatever measures
are necessary to eliminate the interference.
(FCC = Federal Communications Commission in the U.S.A.)
1-3-2 Compliance with EMC Directives
This device features radio interference suppression in compliance with valid EC
Regulation 89/336/EEC.
Table 2 Applicable weighing instruments and key operations
ON:OFF
CAL
Calibrates
using the
external
Turns the
mass.
weighing
Calibrates
instrument
using the
display
internal
on or off.
mass.
*1
AD-8922A key
SAMPLE
PRINT
Switches
the
Outputs
minimum
the
display.
received
*2
data to
an
external
device.
*3
out 1
" or "
These rules are designed to provide
3
MODE
RE-ZERO
Switches
the
response
characteristic.
Sets the
display to
Switches
zero.
the unit
displayed.
*4
out 2
" of the function setting).
Command
set *5
C5et 1
C5et 1
C5et 2
C5et 3
C5et 4
C5et 0