Transmission / Receiving Protocol - LG 42WS50MS Owner's Manual

Monitor signage
Hide thumbs Also See for 42WS50MS:
Table of Contents

Advertisement

72
CONTROLLING THE MULTIPLE PRODUCT

Transmission / Receiving protocol

Transmission
[Command1][Command2][ ][Set ID][ ][Data][Cr]
* [Command 1]: First command. (k, j, m, d, f, x)
* [Command 2]: Second command.(a to u)
* [Set ID]: Set up the Set ID number of product.
range : 01H to 63H. by setting '0', server can control all products.
* In case of operating with more than 2 sets using set ID as '0' at the same time, it should not be checked the ack
message. Because all sets will send the ack message, so it's impossible the check the whole ack messages.
* [DATA]: To transmit command data.
Transmit 'FF' data to read status of command.
* [Cr]: Carriage Return (ASCII code '0 x 0 D')
* [ ]: ASCII code Space (0 x 20)
OK Acknowledgement
[Command2][ ][Set ID][ ][OK][Data][x]
* The Product transmits ACK (acknowledgement) based on this format when receiving normal data. At this time,
if the data is data read mode, it indicates present status data. If the data is data write mode, it returns the data of
the PC computer.
Error Acknowledgement
[Command2][ ][Set ID][ ][NG][Data][x]
* If there is error, it returns NG

Advertisement

Table of Contents
loading

This manual is also suitable for:

47ws50ms42ws50bs47ws50bs

Table of Contents