STK-RCS-7TWSU (Wired Remote Controller)
I Parts supplied with the remote controller
See Table 1.
I Remote controller installation guidelines
Installation location
• Mount the remote controller 3.3 to 4.9 ft. (1 to 1.5
meters) off the floor where it can sense the average
temperature of the room.
• Do not mount the remote controller in a place exposed
to direct sunlight or where it is exposed to outside air
such as near a window.
• Do not mount the remote controller behind a curtain or
other object so that it is separated from the air circula-
tion of the room.
• Mount the remote controller inside the room being air
conditioned.
Switching the room temperature sensor
Room temperature sensors are separately incorporated in both the indoor unit and the remote controller. Either sensor can
be used to sense the room temperature. The indoor unit sensor is usually used.
If you wish the remote controller to sense the room temperature, press the SENSOR button with a ballpoint pen or tool with
a small tip. (Refer to Fig. 9 on page 4 to locate the SENSOR button.)
I How to install the remote controller
IMPORTANT
• The remote controller is set to "Cool/Dry/Heat model" at
the time of shipment from the factory. If the purchased air
conditioner is a COOL/DRY model, follow the instructions
on the label and change the switch on the reverse side of
the remote controller unit to "Cool/Dry model". (Fig. 1)
• The remote controller is also set to "Single" at the time of
shipment from the factory. For multiple use, set the switch
on the reverse side of the remote controller unit to "Multi".
(Fig. 1)
• After all work is completed, if any switches have been
changed, then be sure to press the ACL (Reset) button.
(Refer to Fig. 9 on page 4 to locate the ACL (Reset) but-
ton.)
481
85264190
000 © SANYO 2008
INSTALLATION INSTRUCTIONS
SANYO Commercial Solutions
A Division of SANYO North America Corporation
1300 Michael Drive, Suite A
Wood Dale, IL 60191, U.S.A.
Table 1
Parts
Figure
Q'ty
Wired
remote
1
controller
5/32 15/16"
Machine
(4 25mm)
2
screws
5/32 15/16"
(4 25mm)
Tapping
2
screws
Spacers
2
Fig. 1
Parts
Figure
26.2 ft. (8m)
Wire
harness
Instruction
manual
Installation
Instructions
In Canada
SANYO Canada Inc.
1-300 Applewood Crescent, Concord
Ontario, L4K 5C7, Canada
Q'ty
1
1
1
W

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xs1271Cl1872C1271C1872Cl1271Ch1872 ... Show all