Split System Submittal Data
System: 18KS72
Indoor/Outdoor: KS1872/C1872
Wall Mounted Air Conditioner
Job Name:
Location:
Engineer:
Submitted to:
Submitted by:
Reference:
Power
V/PH/Hz
Circuit Ampacity
(A)
Fuse Size, Max.
(A)
Compressor
No. used
R.L. Amps - L.R.
Crankcase Heater
(W)
Outdoor Unit
Fan type
Dia. (in.) - No. Speeds
Type Drive - No. Speeds
No. Poles
(RPM)
No. Motors
(High)
CFM
F.L. Amps
Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
(sq.ft.)
Face Area
(in.)
Tube Size
Indoor Unit
Fan type
Dia. & Length (in.) - No. Speeds
No. Speeds
(RPM, High)
No. Poles
No. Motors
(HI/Med/Lo)
CFM
Indoor Sound Rating
(Hi) (dB-A)
F.L. Amps
Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
Face Area
(sq.ft.)
Tube Size
(in.)
(in.)
Drain Connection Size
General Data (at 230V)
230/208/1/60
20
20
DC Rotary Inverter
(A)
7 - 17.5
Propeller
16-17/32 - 1
DC Motor
8 - 820
(W)
50 - 1
(A)
Aluminum Fin & Copper Pipe
Corrugated Plate - Inner Riff ed
2 - 21.2
9/32"
Cross Flow
3-11/16 33-9/32 - 1
3 & Auto
8 - 1250
(W)
30 - 1
523/470/417
(A)
Aluminum Plate Fin & Copper Tube
Slit Plate - Inner Riff ed
2 - 19.5
9/32"
23/32"
Approval:
Date:
Construction:
Unit #:
Drawing #:
Refrigerant
Lbs. - R410a (outdoor unit)
Control
1
Connection
Line Length, Max
N/A
Lift Difference, Max
Line Size
Line Size
Dimensions
Indoor Unit
524
Outdoor Unit
0.5
Weight
Net
Shipping
5.49
Shipping Volume
Performance Data @ ARI Standard Conditions (230V)
Cooling
Total Capacity
Sensible Capacity
Latent Capacity
SEER
Dehumidification
42
0.3
Amps
Power Inputs
Outdoor Sound Rating
3.07
Electric Expansion Valve
(in. O.D. Discharge)
(in. O.D. Suction)
(in.)
(Uncrated)
11-23/32 x 41-15/16 x 8-19/32
(Crated)
11-3/8 x 44-7/8 x 14-29/32
(Uncrated)
26-3/8 x 34-21/32 x 11-7/32
(Crated)
29-1/8 x 39-27/32 x 14-31/32
Indoor
(lbs.)
26.5
(lbs.)
33.1
Indoor
(cu.ft.)
4.23
(BTU/H)
17,500 (4,000-17,500)
(BTU/H)
(BTU/H)
(Pints/H)
(A)
(W)
1,500/1,500 (250-1,500)
(dB-A)
R410A
2.87
Flare
100
50
1/4"
1/2"
H x W x D
Outdoor
90.4
99.2
Outdoor
9.88
13,100
4,400
20
4.89
7/7.7
51

Advertisement

loading

Summary of Contents for Sanyo 18KS72

  • Page 1 Split System Submittal Data System: 18KS72 Indoor/Outdoor: KS1872/C1872 Wall Mounted Air Conditioner Job Name: Location: Engineer: Submitted to: Submitted by: Reference: General Data (at 230V) Power V/PH/Hz Circuit Ampacity Fuse Size, Max. Compressor No. used R.L. Amps - L.R. Crankcase Heater...