7-3. Disassembly Procedure

WARNING
7-3-1. Remove the air intake grill.
(1) Slide the 2 latches each to the corresponding arrow direction. (Fig. 1 and Fig. 2)
Open downward the air intake grill located on the latch side.
(2) Undo the air intake grill drop preventive hook. (Fig. 3)
Undo the 2 hinges for the grill and remove the air intake grill.
Air intake grill
Fig.1
7-3-2. Disconnect the connectors in the control box.
(1) Remove the 2 screws and remove the control box cover. (Fig. 4)
(2) Disconnect the connectors CN04 (FLAP 5P), CN12 (RC 4P) and CN13 (IND 7P). (Fig. 5)
Screw
To avoid electrical shock hazard, be sure to disconnect power before
attempting to disassemble the unit.
When a footstool, etc. is used for disassembling the indoor unit,
be careful not to fall down. If you fall down, you might be injured seriously.
Latch
Hinge
Control box cover
Fig.4
Latch
Fig.2
Control PCboard
44
Hinge
Hook
Fig.3
CN04
CN13
CN12
Fig.5