Recommended Wire Length And Diameter; Wiring Instructions For Inter-Unit Connections - Sanyo KS1852 Installation Instructions Manual

Split system
Hide thumbs Also See for KS1852:
Table of Contents

Advertisement

3-7. Recommended Wire Length and Diameter

Regulations on wiring diameter differ from locality to
locality. For field wiring requirements, please refer to
your local electrical codes. Carefully observe these reg-
ulations when carrying out the installation.
NOTE
Refer to the wiring system diagram (Fig. 23)
Refer to your local codes or in the absence of local
codes with the National Electric Code: ANSI/NFPA70.
WARNING
Be sure to comply with local codes on running
the wire from the outdoor unit to the indoor unit
(size of wire and wiring method, etc.).
Each wire must be firmly connected.
No wire should be allowed to touch refrigerant
tubing, the compressor, or any moving part.
WARNING
To avoid the risk of electric shock, each air
conditioner unit must be grounded.
CAUTION
Be sure to connect the power supply line to the
outdoor unit as shown in the wiring diagram. The
indoor unit draws its power from the outdoor
unit.

3-8. Wiring Instructions for Inter-unit Connections

a) Remove the grille. (See 3-4. Remove the Grille to
Install the Indoor Unit on page 8.)
b) Insert the inter-unit wiring (according to local codes)
into the through-the-wall PVC pipe. Run the wiring
toward the indoor side allowing approx. 10 in. (25
cm) to extend from the wall face. (Fig. 24)
CAUTION
Never fix the wiring by any
means before the indoor unit
is fully seated on the rear
panel.
WIRING SYSTEM DIAGRAM
C0951, CL0951, C1251, CL1251 Models
INDOOR
INDOOR UNIT
Terminal
1
2
3
Disconnect
switch
(Field supply)
G
C1852, CL1852 Models
INDOOR
INDOOR UNIT
Terminal
1
2
3
Disconnect
switch
(Field supply)
G
Rear
panel
Wiring
10
OUTDOOR UNIT
(Inter-unit)
Power lines
Terminal
115V
1
115V
Fuse
2
115V
3
4
L
5
N
6
G
Grounding
line
OUTDOOR UNIT
(Inter-unit)
Power lines
Terminal
230/208 V
1
Fuse
230/208 V
2
230/208 V
3
4
L1
5
L2
6
G
Grounding
line
Fig. 23
Wall
Plastic
cover
10 in.
(25 cm)
Fig. 24

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ks0951Ks1251C0951Cl0951C1251Cl1251 ... Show all