JUKI HZL-K85 Service Manual page 33

Hide thumbs Also See for HZL-K85:
Table of Contents

Advertisement

SERVICE MANUAL
4. Insert the inner dial (b) into place after adjustment. Fix wall portion (h)of the inner
dial into position where it is around opposite side of pipe knock pin (e).
Though tension value may be deviated a little from the one adjusted on section 3,,
Re-adjust it in last step.
5. Outside surface of inner dial (b) is knurled and inside surface of outer dial (a)
is partly knurled. The knurled portions of both dials are meshed each other.
Knurled portion
e
Date:
2011/09/23
Page:
33/39
Model:
K65&K85
h
b