14. Hand lifter lever
Disassembly
™ Loosen hand lifter lever shaft set-
screw 4 .
™ Insert M4 screw 3 into tapped
hole in hand lifter lever shaft 2 by
3 to 4 screw threads.
™ Hold screw head and draw out the
screw.
™ At the same time, also draw out
hand lifter lever shaft.
™ Remove hand lifter lever 1 .
15. Drop-feed knob
Disassembly
™ Set 1 drop-feed knob to "NOT
FEED", remove 4 drop feed knob
shaft setscrew, and remove 3
E-ring of drop feed knob.
™ Remove 2 DF adjusting arm
spring while removing 6 DF ad-
justing arm asm..
1 Hand lifter lever
Flat part
2 Hand lifter lever shaft
3 M4 screw
Assembly
™ Put hand lifter lever shaft 2 into
the hole in the frame.
™ Secure hand lifter lever shaft 2
by tightening hand lifter lever
shaft setscrew 4 in such a way
that the tip of setscrew 4 comes
in contact with the flat part on
hand lifter lever shaft 2 .
1 Drop-feed knob
4 Drop feed knob shaft setscrew
Assembly
™ Pass 1 drop feed knob through
5 wire installing plate.
™ Assemble 2 DF adjusting arm
spring while assembling 6 DF
adjusting arm asm..
™ Place 3 E-ring to 1 drop feed
knob.
™ Assemble drop feed knob shaft
with 4 setscrew.
2
4 Hand lifter lever shaft set screw
a
™ End face a of hand lifter lever
shaft 2 should not jut out from
the frame surface.
3 E-ring
5 Wire installing plate asm.
2 DF adjusting arm spring
™ It is easy to remove 2 spring
when 1 drop-feed knob is set to
"NOT FEED" side.
Point
6 DF adjusting arm asm.
Point